9
TROUBLESHOOTING (cont.)
PROBLEM
Product will not dispense (cont.)
Water is not hot
PROBABLE CAUSE
5. Solenoid Valve (Inlet)
6. Control Board #1 and Probe
7. Auger Drive
8. Water Strainer
9. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up on
stainless steel surfaces can initiate
corrosive reactions resulting in seri-
ous leaks.
10. Transformer
1. Limit Thermostat
CAUTION -
Do not eliminate or by-
pass limit thermostat. Use only BOM
replacement part #29329.1000
2. Control Thermostat
3. Tank Heater
REMEDY
Refer to
Service
- Solenoid Valve
(Inlet) for testing procedures. See
page 37
Refer to
Service
- Control Board
and Probe for testing procedures.
See page 20
Refer to
Service
- Auger Drive. See
page 13 & 15
Remove the strainer and check for
obstructions. Clear or replace.
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Refer to
Service
- Transformer for
testing procedures. See page 41
Refer to
Service
- Limit Thermostat
for testing procedures. See page
31
Refer to
Service
- Control Ther-
mostat for testing procedures. See
page 19
Refer to
Service
- Tank Heater for
testing procedures. See page 38
35135 012103