background image

7

COLD BEVERAGE SET-UP  (OPTIONAL)

Cold beverages may be dispensed from the left dispense position.  Simply place the HOT/COLD switch near the 

left whipper chamber in the “COLD” (upper) position.

ADJUSTMENTS

The hot or cold beverage solenoids  are preset to dispense approximately 

9

/

10 

ounce per second.  This amount 

can be adjusted:

1.  Disconnect the dispenser from the power source.

2.  Remove the small left side access panel.

3.   Rotate the control at the base of the desired solenoid(s) clockwise to decrease or counterclockwise to increase 

the amount of water.

4.  For cold beverage adjustment remove the 1-1/2" plug on the lower left side of the dispenser and rotate the 

needle valve clockwise to decrease or counterclockwise to increase the amount of cold water.   

HOPPER DISPENSE RATE OF PRODUCT

NOTE: The hopper dispense rates are preset at the factory. With 22 tooth gear and auger wire the preset dis-

pense rate is approximately 3 to 5 grams per second. With 30 tooth gear and auger wire the preset dispense is 

approximately 5 to 7 grams per second. The hopper dispense rates can be individually programmed to a range 

of dispense rates from approximately 1.5 to 12 grams per second, as follows:

1.  Place the rinse/run switch in the center (program) position.

2.   Hold the increase/decrease switch in the desired (increase or decrease) position.

3.  While holding the increase/decrease switch, press and release the dispense switch for the chamber you wish 

to adjust. Each time the dispense switch is pressed, the rinse L.E.D. will flash, and the motor speed for that 

hopper will be increased/decreased by approximately 2 1/2%.

4.  Return the rinse/run switch to the run position after hopper motor speed adjustments are complete.

5.   Once any of the three hopper motors has been programmed to the desired speed, either or both of the other 

hopper motors can be set to the same speed as follows:

 

a. Place the rinse/run switch in the center (program) position.

 

b. Press and hold the dispense switch that has been programmed for the correct speed.

NOTE: Care must be taken not to exceed 5 seconds, or a hopper throw test will occur.

 

c. Momentarily press the dispense switch for the hopper motor to be programmed. The rinse L.E.D. will light 

for approximately 1 second, indicating that the speeds have been set equal.

 

d. Release both dispense switches.

 

e. Repeat step 5. b. through 5. d. for remaining hopper motor if desired.

 

f. Return the rinse/run switch to the run position after hopper motor speed adjustments are complete.

HOPPER THROW TEST

The hopper throw rate, grams per second (g/s) or ounces per second (oz./s), can be checked by automatically

running the hopper motor for 10 seconds.

1.   Remove the steam collector and mixing chamber from under the hopper to be checked.

2.  Position a small cup under the hopper outlet.

3.  Place the rinse/run switch in the center (program) position.

4.   Press and hold the dispense switch of the appropriate chamber for 5 seconds. The hopper  motor will run 

for 10 seconds at the programmed speed.

5.   Remove the cup and weigh the dispensed product.  To calculate the throw rate (g/s or oz./s), divide the total 

weight of the dispensed product by 10.

6.   Replace the mixing chamber and steam collector, and return the rinse/run switch to the run position.

29170 060509

Summary of Contents for FMD-3

Page 1: ...he latest revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates For Technical Service contact Bunn O Matic Corporation at 1 800 286 6070 29170 0000J 05 11 1998 Bunn O Matic Corporation ...

Page 2: ... sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specified above to repair the defective components provided that this repair is done by a BUNN Authorized Service Representative or 2 shall re...

Page 3: ...60 HEATER TEMPERATURE ADJUSTMENT 26527 0003 THERMOSTAT ASSEMBLY 120VAC BUNN O MATIC CORP ELECTRONIC THERMOSTAT 26536 0003 USER NOTICES Carefully read and follow all notices on the equipment and in this manual They were written for your protection All notices are to be kept in good condition Replace any unreadable or damaged labels 29170 051111 28368 0004 CONTROL THERMOSTAT ADJUSTMENT APPROXIMATE T...

Page 4: ...r at the electrical source 3 Open the front door of the dispenser and place the heater switch in the OFF upper position 4 Connect the dispenser to the power source 5 If plumbing is to be hooked up later be sure the dispenser is disconnected from the power source If plumbing has been hooked up the dispenser is ready for Initial Fill Heat CE REQUIREMENTS This appliance must be installed in locations...

Page 5: ... dispenser The size and shape of the hole made in the supply line by this type of device may restrict water flow 29170 051111 PLUMBING HOOK UP Early Models 1 Securely attach the short piece of tubing on the water strainer assembly to the inlet fitting on the bottom of the dispenser 2 Flush the water line and securely attach it to the flare fitting on the water strainer assembly 3 Turn on the water...

Page 6: ...ll flash about once every 5 seconds Once the cause of the refill error has been investigated see the troubleshooting guide and cured the system can be reset by disconnecting for at least 5 seconds and then reconnecting the power to the machine RINSE TIMER The dispenser is shipped from the factory with the rinse timer disabled To enable the rinse timer remove power from the dispenser remove the low...

Page 7: ...d the motor speed for that hopper will be increased decreased by approximately 2 1 2 4 Return the rinse run switch to the run position after hopper motor speed adjustments are complete 5 Once any of the three hopper motors has been programmed to the desired speed either or both of the other hopper motors can be set to the same speed as follows a Place the rinse run switch in the center program pos...

Page 8: ...a deberá realizarse diariamente 1 x 7d 1 2 3 4 5 a Wash b Rinse c Sanitize d Dry a Lave b Enjuague c Desinfecte d Seque 7 8 6 a b c 9 7 Replace Light Bulbs as required 1 Para limpiar las camaras de mezcla coloque el interruptor en la posicón ENJUAGUE MARCHA RINSE RUN y pulse el boton para espumar y distribuir la bebida DISPENSE 2 Gire el codo hacia arriba remueva las tolvas llene las tolvas con pr...

Page 9: ...t NOTE The dispenser must be refilled using the INITIAL FILL HEAT steps before reconnecting to the power source 29170 011510 PREVENTIVE MAINTENANCE Bunn O Matic Corporation recommends that preventive maintenance be performed at regular intervals Maintenance should be performed by a qualified service technician For Technical Service contact Bunn O Matic Corporation at 1 800 286 6070 NOTE Replacemen...