5
PLUMBING REQUIREMENTS
This dispenser
must be connected to a cold water system with operating pressure between 20 and 90 psi (138
and 620 kPa) from a 1/2˝ or larger supply line. A shut-off valve should be installed in the line before the brewer.
Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The
water inlet fitting is .75-11.5 NH (HOSE THREAD). For convenience an elbow adaptor is provided to convert to
a 1/4˝ flare fitting. Bunn-O-Matic does not recommend the use of a reverse-osmosis or deionized water supply
to this equipment. REQUIRED: 1.0 gpm (3.78 lpm) flow rate from water supply line.
NOTE - At least 18 inches of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene
or silicone, before the dispenser will facilitate movement to clean the countertop. Bunn-O-Matic does not recom-
mend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line
by this type of device may restrict water flow.
29170 051111
PLUMBING HOOK-UP (Early Models)
1. Securely attach the short piece of tubing on the water strainer assembly to the inlet fitting on the bottom of
the dispenser.
2. Flush the water line and securely attach it to the flare fitting on the water strainer assembly.
3. Turn-on the water supply.
PLUMBING HOOK-UP (Late Models)
1. Flush the water line and securely attach it to the elbow fitting on the bottom of the dispenser.
2. Turn-on the water supply.
NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed
and maintained in accordance with federal, state and local codes.
As directed in the International Plumbing Code of the International Code Council and the Food Code
Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate
backflow prevention to comply with federal, state and local codes. For models installed outside the
U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.