background image

Page 5

ELECTRICAL REQUIREMENTS

120V AC 

Single phase models

Note:

 This electrical service re-

quires 2 current carrying conduc-
tors (Neutral, and L1) and a separate 
conductor for earth ground.

Requirements for brewers without an attached cord set are as follows:

Requirements for brewers with an attached cord set are as follows:

120V

120/208-240V

For Supply Connections, Use No. 12 AWG

Wires Suitable For At Least 90

o

C (194

o

F)

FOR USE ONLY ON AN

INDIVIDUAL BRANCH

CIRCUIT RATED 20 AMPS

120V

120/208-240V

For Supply Connections, Use No. 12 AWG

Wires Suitable For At Least 90

o

C (194

o

F)

FOR USE ONLY ON AN

INDIVIDUAL BRANCH

CIRCUIT RATED 20 AMPS

Dual Voltage Switch in 

120V position

Dual Voltage Switch in 
120/208-240V position

120/208 & 120/240V AC 

Single phase models

Note:

 This electrical service 

require 3 current carrying 
conductors (Neutral, L1 and 
L2) and a separate conductor 
for earth ground

Single & Dual Volt Models

N

L1

G

L2 RED

L2 RED

POWER CORD

WHITE

GREEN

NEUTRAL

L1 BLACK

WHITE

NEUTRAL

L2

L1 BLACK

WHITE

NEUTRAL

L1 BLACK

N

L1

G

POWER CORD

GREEN

WHITE

NEUTRAL

L1 BLACK

L2 RED

L2 RED

L2

L1 BLACK

L1

G

POWER CORD

GREEN

L1 BLACK

120/208-240V 3 WIRE + GROUND

120V 2 WIRE + GROUND

240V 2 WIRE + GROUND

L2 RED

NEUTRAL BLUE

N

L1 BLACK

L1

G

POWER CORD

GREEN/YELLOW

L1 BROWN

230V 2 WIRE + GROUND

A &B Models

39130.1 060810

Summary of Contents for Axiom-APS SERIES

Page 1: ...the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to...

Page 2: ...its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or...

Page 3: ...servicing 03408 0002 03409 0002 12364 0000 00656 0001 As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration FDA...

Page 4: ...e switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plumbing has been h...

Page 5: ...At Least 90oC 194oF FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Single phase models...

Page 6: ...e brewer to clean the counter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may rest...

Page 7: ...elected batch to brew Also used in programming to adjust settings on both batch sizes D MAIN ON OFF SWITCH This switch located on the left side of the brewer or rear panel turns power on and off to al...

Page 8: ...It will help prevent liming problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable...

Page 9: ...Screen This is the display which shows the various functions 2 Right Hidden Switch Press and hold to view the currently assigned recipe Holding longer will enter BrewWIZARD programming mode and is al...

Page 10: ...ORD 0 0 0 EXITING BrewWIZARD SELECT RECIPE NO YES PROGRAMMING FUNCTIONS FLOW CHART CONT BrewWIZARD ENTER SERVICE NO YES SET PASSWORD 0 0 0 ENTER SERIAL NO YES DRIP TIME 0 30 DONE SET PULSE BREW NO YES...

Page 11: ...ONE YES EnableFreshTimer NO DONE YES ENABLE CLEAN NO DONE YES These two screens will change if BrewLogic is enabled SET READY 195 DONE ENTER ASSET NO YES SET LANGUAGE NO YES UNITS METRIC DONE ENG BREW...

Reviews: