Page 4

ELECTRICAL REQUIREMENTS

WARNING

 - 

The brewer must be disconnected from the power source until specifi ed in Initial Set-Up.
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.

ELECTRICAL HOOK-UP (All Models)
CAUTION

 – Improper electrical installation will damage electronic components. 

1. 

An electrician must provide electrical service.

2. 

Determine the available on-site electrical service.

3. 

Select the desired unit voltage based on the available on-site electrical service.

4. 

Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

5. 

Remove the front access panel beneath the sprayhead to gain access to the terminal block.

6. 

Feed the supply leads through the rear of the brewer.

7. 

Using the above diagrams, connect the desired electrical service to the fi eld wiring terminal block.

8. 

If wiring the machine for operation on 120/208 or 120/240 volts with a Power Supply Cord, the Power 
Supply Cord must be UL Listed Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4 Con-
ductor, Rated 90° C. Attachment Plug Cap must be UL Listed, NEMA 14-20P or L14-20P Confi guration, 
Rated 125/250V, 20 AMPS. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long 
(measured from Strain Relief to end of the Attachment Plug Cap).

9. 

Before proceeding, verify the voltage at the fi eld wiring terminal block.

10.  Set voltage switch to the appropriate position and replace the access panel. (DV Models Only)
11.  If plumbing is to be hooked up later be sure the brewer is disconnected from the power source.  If 

plumbing has been hooked up, the brewer is ready for Initial Set-Up.

Note:

 This electrical service requires 3 

current carrying conductors (Neutral, 
L1 and L2) and a separate conductor 
for earth ground.

Note:

 Power cord must be 

connected to center terminal 
block on all Twins unless 
otherwise noted.

Twins

CE REQUIREMENTS

• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specifi ed in conformance with all local and national codes.
• This appliance must not be cleaned by water jet.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of 
this appliance by a person responsible for its safety.
• Children should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with 
a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
• Machine must not be immersed for cleaning.

All Twins are 120/208 & 120/240V AC 

Single phase unless otherwise noted.

39130.1 060810

Summary of Contents for Axiom-APS SERIES

Page 1: ...the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to...

Page 2: ...its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or...

Page 3: ...servicing 03408 0002 03409 0002 12364 0000 00656 0001 As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration FDA...

Page 4: ...e switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plumbing has been h...

Page 5: ...At Least 90oC 194oF FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Single phase models...

Page 6: ...e brewer to clean the counter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may rest...

Page 7: ...elected batch to brew Also used in programming to adjust settings on both batch sizes D MAIN ON OFF SWITCH This switch located on the left side of the brewer or rear panel turns power on and off to al...

Page 8: ...It will help prevent liming problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable...

Page 9: ...Screen This is the display which shows the various functions 2 Right Hidden Switch Press and hold to view the currently assigned recipe Holding longer will enter BrewWIZARD programming mode and is al...

Page 10: ...ORD 0 0 0 EXITING BrewWIZARD SELECT RECIPE NO YES PROGRAMMING FUNCTIONS FLOW CHART CONT BrewWIZARD ENTER SERVICE NO YES SET PASSWORD 0 0 0 ENTER SERIAL NO YES DRIP TIME 0 30 DONE SET PULSE BREW NO YES...

Page 11: ...ONE YES EnableFreshTimer NO DONE YES ENABLE CLEAN NO DONE YES These two screens will change if BrewLogic is enabled SET READY 195 DONE ENTER ASSET NO YES SET LANGUAGE NO YES UNITS METRIC DONE ENG BREW...

Reviews: