PA3/PA3IS - Principle of Operation

The PA30 Powered Air-Purifying Respirator (PAPR) System is
supplied in six parts:

1. The blower assembly (Part No. PA3/PA3IS) which includes:

PA3BU Blower Unit or PA3ISBU Blower Unit
PA1SB Belt or PA1DB Decon Belt
PA1AFI Air Flow Indicator

2. The battery pack (Part No. PA3BP). One or two packs can be

used. One fully charged pack will power the blower for
approximately four to five hours. For Part No. PA3ISBP, one
battery pack is used, lasting approximately seven hours.

3. The breathing tube, which is available in two different types

and two lengths:

PA1BT Hood Breathing Tube Assembly with Clamp
(Standard Length)
PA1BTXS Hood Breathing Tube Assembly with Clamp
(Short Length)
PA20LFBT Loose Fitting Facepiece Breathing Tube Assembly 
(Standard Length)
PA20LFBTXS Loose Fitting Facepiece Breathing Tube Assembly
(Short Length)

4. The cartridges are available in different types for most toxic

contaminants. (See page 6 for a listing of the cartridges.) The
types include High Efficiency particulate only, chemical
cartridges for gases and vapors, and combination cartridges
for gases, vapors and particulates.

5. The hood with headband suspension and/or hard hat, or loose

fitting facepiece. The following hood models may be used with
the PA3BU/PA3ISBU blower unit:

RT1/RT2 Hood with long inner and outer bib
20TJ Hood
20TIC Hood with Inner Bib
20TICH Hood for use with Bullard Hard Hat
20TICS Hood with Taped and Sealed Seams
20SIC Hood with Taped and Sealed Seams
20SICV Hood with Taped and Sealed Seams and CBRN-resistant
PVC lens
20SICH Hood with Taped and Sealed Seams for use with
Bullard Hard Hat
20SICVH Hood with Taped and Sealed Seams and CBRN-
resistant PVC lens for use with Bullard Hard Hat
20TPC Hood with Solvent Resistant Lens and Inner Bib
20TP Hood with Solvent Resistant Lens
20LFM Loose Fitting Facepiece Hood, Medium Size
20LFL Loose Fitting Facepiece Hood, Large Size

6. The Battery Charger:

PA3SMC Quick Charger
PA3GC Gang Charger
PA3ISC Intrisically Safe Quick Charger
PA3ISGC Intrinsically Safe Gang Charger

The blower unit draws in ambient air through the cartridges. The
purified air is blown into the wearer’s hood through the breathing
tube. A flow indicator is provided to check that there is an
adequate volume of air available to the wearer prior to use.

The units are designed for use at temperatures from 10ºF to 120ºF
(-12ºC to 49ºC).

The system is designed to operate at a minimum air flow of
approximately seven cubic feet of air per minute (210 liters per
minute) in the hood under normal use. 

The battery pack(s) mount in compartment(s) on the back of the
blower. One fully charged battery pack will power the blower for
approximately four to five hours (PA3BU) or approximately seven
hours (PA3ISBU). Two fully charged packs (PA3BU) will run for
approximately eight hours.

The PA3BU/PA3ISBU is fitted with an alarm which will sound when
voltage is low.

CC20 and RT Series Airline Respirator
NIOSH Approval No. TC-19C-154, Type C and
TC-19C-412, Type C

Most of the same headpieces approved for use with the CC20 and
RT Series of supplied air respirators (SARS) are also approved for
use with the PA30 Series of powered air-purifying respirators.
CC20 and RT  Series respirators provide a high level of respiratory
protection and user comfort over long work periods, in a wide
variety of hazardous environments. 

The CC20 and RT SAR air flow control devices and other
components are described in the CC20 and RT Series User
Instructions.

Principle o

f Oper

ation

3

www.bullard.com

 

Summary of Contents for PA30 Series

Page 1: ...espiratory protection during abrasive blasting or clean up 4 Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as established by regulatory standards 5 Leave area immediately if Breathing becomes difficult Dizziness or other distress occurs You taste or smell the contaminant Unit becomes damaged Voltage a...

Page 2: ...erational Inspection 4 Mounting the Breathing Tube 5 Checking Air Flow 5 Air Purifying Elements 6 Mounting and Replacing Cartridges 7 Donning the Blower 8 Low Battery Alarm 8 Troubleshooting 9 Cleaning and Storage 9 NIOSH Approval Label 10 11 Ordering Information 12 Table of Contents 2 www bullard com ...

Page 3: ...Hat 20SICVH Hood with Taped and Sealed Seams and CBRN resistant PVC lens for use with Bullard Hard Hat 20TPC Hood with Solvent Resistant Lens and Inner Bib 20TP Hood with Solvent Resistant Lens 20LFM Loose Fitting Facepiece Hood Medium Size 20LFL Loose Fitting Facepiece Hood Large Size 6 The Battery Charger PA3SMC Quick Charger PA3GC Gang Charger PA3ISC Intrisically Safe Quick Charger PA3ISGC Intr...

Page 4: ... is fully charged This procedure should also be followed after periods of prolonged storage Without periodic charging the nickel metal hydride batteries will lose up to 1 2 of their charge per day Allowing a battery to self discharge during periods of prolonged storage will not damage the battery Pre Operational Inspection Prior to each work shift perform the following Pre Operational Inspection t...

Page 5: ... not blocked Two hands may be used if preferred one to hold the breathing tube and one to hold the Airflow Indicator The position of the ball in the Airflow Indicator should be observed If any part of the ball is below the PASS LINE on the Airflow Indicator check for Blower malfunction Clogged or damaged Air Purifying filter elements on the HE filters or the combination cartridges with HE filters ...

Page 6: ...inst the following contaminants independent laboratories have tested and verified that the PA3NBC cartridge is effective against many chemical warfare agents and or their recognized surrogates These agents surrogates are listed below WARNING Use only the cartridge described in the above table Used particulate laden cartridges must be changed as a set and not individually All cartridges must be of ...

Page 7: ...cts of the gas or vapor and the presence of any warning properties Contact Bullard for further information on change out schedules High efficiency particulate filters must be replaced when retained particles clog the filters and reduce air flow below acceptable levels as indicated by testing with the Air Flow Indicator See page 5 To Replace Cartridges Remove the air purifying element from its pack...

Page 8: ... if the battery voltage is below acceptable levels The PA3BU Low Voltage Alarm is an electronic 77 dba beep The PA3ISBU Low Voltage Alarm is a mechanical pulsing of the blower In either case the alarm is internal to the blower and the sound will be carried up the breathing tube into the hood Sounding of the alarm indicates that insufficient airflow may be imminent The user should immediately do th...

Page 9: ...ne organic based solvents or chlorinated degreasing fluids such as trichloroethylene as they will cause damage DO NOT immerse the equipment in water or other cleaning fluid as this may cause contamination in the breathing tube and blower interior that will be difficult to remove Failure to observe the instructions and warnings in this manual invalidates all performance statements and approvals for...

Page 10: ...s for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenanc...

Page 11: ... for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenance...

Page 12: ...olvent resistant polyester lens no suspension CC20 only Hood with inner bib for use with Bullard hard hat 20TICH Tychem QC hard hat not included 20SICH Tychem SL with taped and sealed seams hard hat not included 20SICVH Tychem SL with taped and sealed seams and CBRN resistant PVC lens hard hat not included Hood with inner bib and long outer bib for use with headband suspension 20TICS Tychem QC wit...

Reviews: