Chapter 2: Server Installation
2-11
2-5 Checking the Serverboard Setup
After you install the bullx R424-E2/R424-INF-E2 or R424-F2/R424-INF-F2 in the
rack, you will need to open the top cover to make sure the serverboard is properly
installed and all the connections have been made.
Accessing the Inside of the System
Release the retention screws that secure the system to the rack.
1.
Grasp the two handles on either side and pull the system straight out until it
2.
locks (you will hear a "click").
Remove the four screws (two on the sides and two on the top) that secure
3.
the top cover to the chassis. Place your thumbs in the two rectangular recess-
es and push the cover away from you (toward the rear of the chassis) until it
stops. You can then lift the top cover from the chassis to gain full access to
the inside of the server (see Figure 2-7).
To remove the system from the rack completely, depress the locking tabs in
4.
the chassis rails (push the right-side tab down and the left-side tab up) to
continue to pull the system out past the locked position.
Checking the Components and Setup
You may have one or two processors already installed in each of the two
1.
serverboards. Each processor needs its own heatsink. See Chapter 5 for
instructions on processor and heatsink installation.
Your server system may have come with system memory already installed.
2.
Make sure all DIMMs are fully seated in their slots. For details on adding
system memory, refer to Chapter 5.
You can install two add-on cards to the system. See Chapter 5 for details on
3.
installing PCI add-on cards.
Make sure all power and data cables are properly connected and not blocking
4.
the chassis airfl ow. See Chapter 5 for details on cable connections.
Summary of Contents for R424-E2
Page 2: ......
Page 12: ...X bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide...
Page 20: ...1 8 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide Notes...
Page 29: ...Chapter 2 Server Installation 2 9 Figure 2 6 Installing into a rack...
Page 38: ...3 4 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide Notes...
Page 86: ...5 44 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide Notes...
Page 103: ...Chapter 6 Advanced Chassis Setup 6 17 Figure 6 24 Placing air shroud on the serverboard...
Page 146: ...8 34 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide...
Page 148: ...A 2 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide Notes...
Page 158: ...B 10 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide...
Page 178: ...C 20 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide...
Page 180: ...D 2 bullx R424 E2 R424 INF E2 and R424 F2 R424 INF F2 Installation and User s Guide...
Page 181: ......
Page 182: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 61FE 01...