Chapter 7: BIOS
7-25
Set PEF Configuration
Set this feature to configure the Platform Event Filter (PEF). PEF interprets BMC
events and performs actions based on pre-determined settings or 'traps' under
IPMI 1.5 specifications. For example, powering the system down or sending an
alert when a triggering event is detected.
The following will appear if PEF Support is set to Enabled. The default is
Disabled
.
PEF Action Global Control
- These are the different actions based on BMC
events. The options are
Alert
, Power Down, Reset System, Power Cycle, OEM
Action, Diagnostic Interface.
Alert Startup Delay
- This feature inserts a delay during startup for PEF alerts.
The options are Enabled and
Disabled
.
PEF Alert Startup Delay
- This sets the pre-determined time to delay PEF
alerts after system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5
Specification for more information at www.intel.com. The options are
No Delay
,
30 sec, 60 sec, 1.5 min, 2.0 min.
Startup Delay
- This feature enables or disables startup delay. The options are
Enabled and
Disabled
.
PEF Startup Delay
- This sets the pre-determined time to delay PEF after
system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5 Specification
for more information at www.intel.com. The options are
No Delay
, 30 sec, 60
sec, 1.5 min, 2.0 min.
Event Message for PEF Action
- This enables of disables Event Messages for
PEF action. Refer to Table 24.6 of the IPMI 1.5 Specification for more informa
-
tion at www.intel.com. The options are
Disabled
and Enabled.
BMC Watch Dog Timer Action
Allows the BMC to reset or power down the system if the operating system
hangs or crashes. The options are
Disabled
, Reset System, Power Down,
Power Cycle.
BMC Watch Dog TimeOut [Min:Sec]
This option appears if BMC Watch Dog Timer Action (above) is enabled. This
is a timed delay in minutes or seconds, before a system power down or reset
after an operating system failure is detected. The options are
[5 Min]
, [1 Min],
[30 Sec], and [10 Sec].
Summary of Contents for Novascale R423-E2
Page 1: ...NOVASCALE R423 E2 Installation and User s Guide REFERENCE 86 A1 52FA 00 ...
Page 2: ......
Page 10: ...Notes viii NovaScale R423 E2 Installation and User s Guide ...
Page 16: ...1 6 NovaScale R423 E2 Installation and User s Guide Notes ...
Page 21: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing Chassis Rails ...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 2 Installing the Server into a Rack ...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System ...
Page 30: ...NovaScale R423 E2 Installation and User s Guide 3 4 Notes ...
Page 110: ...7 30 NovaScale R423 E2 Installation and User s Guide Notes ...
Page 112: ...A 2 NovaScale R423 E2 Installation and User s Guide Notes ...
Page 122: ...B 10 NovaScale R423 E2 Installation and User s Guide ...
Page 142: ...C 20 NovaScale R423 E2 Installation and User s Guide ...
Page 144: ...D 2 NovaScale R423 E2 Installation and User s Guide Notes ...
Page 145: ......
Page 146: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 52FA 00 ...