92
novascale Blade BL465 - Installation and User's Guide
10.
Perform the firmware update by following the instructions that are in the firmware
update package readme file.
11.
Copy the downloaded firmware update package into a directory.
12.
From a command line, type
filename
-s, where
filename
is the name of the executable
file that you downloaded with the firmware update package.
13.
Reboot the server and verify that it completes POST (see
Turning off the blade server
on page 16 and
Turning on the blade server
on page 15).
14.
Turn off the server (see
Turning off the blade server
on page 16).
15.
Remove the blade server form the Blade Chassis (see
Removing the blade server from
the Blade Chassis
on page 25).
16.
Remove the server cover. See
Removing the blade server cover
on page 26.
17.
Move the UEFI boot block recovery switch (SW2-7) to the OFF position (see
System-
board switches
in section 2.8.2 of the
Problem Determination and Service Guide
).
18.
Replace the cover and reinstall the blade server in the Blade Chassis, making sure that
the media tray is selected by the relevant blade server. See
Installing the blade server
cover
on page 60 and
Installing the blade server in a Blade Chassis
on page 62.
19.
Restart the blade server (see
Turning off the blade server
on page 16 and
Turning on
the blade server
on page 15). The system begins the power-on self-test (POST).If this
does not recover the primary bank continue with the following steps.
20.
Remove the blade server form the Blade Chassis (see
Removing the blade server from
the Blade Chassis
on page 25).
21.
Remove the server cover. See
Removing the blade server cover
on page 26.
22.
Reset the CMOS by removing the battery (see
Removing the battery
in section 5.9 of
the
Problem Determination and Solving Guide
).
23.
Leave the battery out of the server for 5 minutes.
24.
Reinstall the battery (see
Installing the battery
in section 5.9 of the
Problem
Determination and Solving Guide
).
25.
Replace the cover and reinstall the blade server in the Blade Chassis, making sure that
the media tray is selected by the relevant blade server. See
Installing the blade server
cover
on page 60 and
Installing the blade server in a Blade Chassis
on page 62.
26.
Restart the blade server (see
Turning on the blade server
on page 15).
The system begins the power-on self-test (POST).
Summary of Contents for Novascale Blade BL465
Page 1: ...novascale Blade BL465 Installation and User s Guide novascale Blade REFERENCE 86 A1 68FE 03...
Page 2: ......
Page 9: ...Safety vii Safety...
Page 10: ...viii novascale Blade BL465 Installation and User s Guide Safety statements...
Page 11: ...Safety ix...
Page 12: ...x novascale Blade BL465 Installation and User s Guide...
Page 13: ...Safety xi...
Page 14: ...xii novascale Blade BL465 Installation and User s Guide...
Page 36: ...22 novascale Blade BL465 Installation and User s Guide...
Page 110: ...96 novascale Blade BL465 Installation and User s Guide...
Page 112: ...98 novascale Blade BL465 Installation and User s Guide...
Page 126: ...112 novascale Blade BL465 Installation and User s Guide...
Page 127: ......
Page 128: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 68FE 03...