Web-Based Network Management
103
Join Timer (centisecs)
Specifies the time between the transmission of GARP PDUs registering (or re-registering)
membership for a VLAN or multicast group in centiseconds. An instance of this timer exists
for each GARP participant for each port. Permissible values are 10 to 100 centiseconds (0.1
to 1.0 seconds). The factory default is 20 centiseconds (0.2 seconds).
Leave Timer (centisecs)
Specifies the time to wait after receiving an unregister request for a VLAN or multicast
group before deleting the associated entry, in centiseconds. This allows time for another
station to assert registration for the same attribute in order to maintain uninterrupted service.
An instance of this timer exists for each GARP participant for each port. Permissible values
are 20 to 600 centiseconds (0.2 to 6.0 seconds). The factory default is 60 centiseconds (0.6
seconds).
Leave All Timer (centisecs)
This Leave All Time controls how frequently LeaveAll PDUs are generated. A LeaveAll
PDU indicates that all registrations will shortly be deregistered. Participants will need to
rejoin in order to maintain registration. An instance of this timer exists for each GARP
participant for each port. The Leave All Period Timer is set to a random value in the range of
LeaveAllTime to 1.5*LeaveAllTime. Permissible values are 200 to 6000 centiseconds (2 to
60 seconds). The factory default is 1000 centiseconds (10 seconds).
Switch configuration
Use this panel to Enable or Disable GVRP and GMRP for this switch. Note: It can take up to 10
seconds for GARP configuration changes to take effect.
GVRP Mode
Choose the GVRP administrative mode for the switch by selecting Enable or Disable from
the pull-down menu. The factory default is Disable.
Summary of Contents for 1GB Intel Ethernet Switch Module
Page 2: ......
Page 26: ...xxiv NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 42: ...16 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 177: ...Web Based Network Management 151 ...
Page 178: ...152 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 254: ...228 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 256: ...230 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 258: ...232 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 266: ...240 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 276: ...250 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 295: ...Understanding and Troubleshooting the Spanning Tree Protocol 269 ...
Page 304: ...278 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Page 307: ......
Page 308: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 23ER 00 REFERENCE ...