ale R423 Installation and User's Guide
2-4 Installing the System into a Rack
This section provides information on installing the NovaScale R423 into a rack unit.
If the NovaScale R423 has already been mounted into a rack, you can skip ahead
to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. The following is a guideline for
installing the system into a rack with the rack rails provided. You should also refer
to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received a total of six rack rail sections with the NovaScale
R423. Two of these sections secure directly to the NovaScale R423 and the third
(which actually consists of two joined sections) secures directly to the rack itself.
All screws and hardware mentioned in the installation steps should be included in
the hardware kit.
Refer to Figure 2-1 to determine which rail section gets attached to the front of the
chassis and which gets attached to the rear of the chassis. (The longer of the two
is the front section. The third rail section attaches to the rack.)
Installing the Chassis Rails
Position the front and rear chassis rail sections along the side of the NovaScale
R423 making sure the screw holes line up. Note that these two rails are left/right
specifi c.Screw the front chassis rail (the long piece) securely to the side of the chas-
sis (see Figure 2-1, step 1). There should be two screws for each side. Repeat this
procedure for the other rail on the opposite side of the chassis. Then attach the two
rear chassis rails to the chassis in the same manner, again keeping in mind that
the rails are left/right specifi c. (You will also need to attach the rail brackets when
installng into a telco rack.)
Locking Tabs:
Both front chassis rails and the rack rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Summary of Contents for NovaScale R423
Page 1: ...NovaScale R423 Installation and User s Guide NOVASCALE REFERENCE 86 A1 95EW 00...
Page 2: ......
Page 10: ...Notes viii NovaScale R423 Installation and User s Guide...
Page 16: ...1 6 NovaScale R423 Installation and User s Guide...
Page 21: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing Chassis Rails...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 2 Installing the Server into a Rack...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System...
Page 30: ...NovaScale R423 Installation and User s Guide 3 4 Notes...
Page 60: ...5 26 NovaScale R423 Installation and User s Guide Notes...
Page 100: ...A 6 NovaScale R423 Installation and User s Guide Notes...
Page 106: ...B 6 NovaScale R423 Installation and User s Guide Notes...
Page 140: ...E 4 NovaScale R423 Installation and User s Guide Notes...
Page 143: ......
Page 144: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 95EW 00...