D-14
NovaScale R422 Installation and User's Guide
Rebuilding Arrays
If an array Build process is interrupted or if a critical member is missing, a Rebuild must
be performed to restore its functionality. For a critical array rebuild operation, the optimal
drive is the source drive.
From the Main Menu, select
Manage Arrays
(as shown in the screen below). From the
List of Arrays, select the array you want to Rebuild.
Press <
Ctrl>
and
<R>
to Rebuild.
1.
2.
NOTE:
Rebuilding applies to Fault Tolerant array (RAID 1) only.
NOTE:
If no spare array exists and a hard disk drive fails, you need to create a spare
before you can rebuild an array.