Bukh DV36 RME Owner'S Handbook Manual Download Page 23

OPERATING MANUAL FOR BUKH DV36RME LIFEBOAT ENGINES 

009W4326-R08 

- 23 - 

 

Keppel Sea Scan Pte Ltd 
No. 44 Benoi Road 
Singapore 629904 

SINGAPORE 

Tel: +65-6863-0788 
Fax: +65-6863-6960 
E-mail: 

[email protected]

 

Contact: Ms Sherry Li Shaoling 

Southern Marine Workshops CC 
3 Carlisle Street, Paarden Eiland 
Cape Town, 7405 

SOUTH AFRICA 

Tel: +2721 5102420 
Fax: +2721 5102467 
E-mail: 

[email protected]

 

Website: 

www.southernmarine.co.za

 

Contact: Clive Wienand 

Jiménez Conesa S.L. 
Puerto Pesquero s/n 
04002  Almería 

SPAIN 

Tel: +34-950-258948 / 235952 
Fax: +34-950-264926 
E-mail: 

[email protected]

 

Contact: Rafael Jiménez Boix 

Jimenez Conesa 
C/. Carlos V, 25 
52006 Melilla 

SPAIN

 

Tel: +34-95-2673379 / 2672678 
Fax: +34-95-2673831 

Náutica Toni Socias S.L. 
Plaza Navegación 6 
07013  Palma de Mallorca 

SPAIN

 

Tel: +34-971-455641 
Fax: +34-971-455890 
E-mail: 

[email protected]

 

Website: 

www.dinatec.net

 

Contact: Antonio Socias 

Industrial & Marine Development Co (Pvt) Ltd 
9/3, #6, Rajakeeya Mawata 
Colombo 7 

SRI LANKA

 

Tel: +94-1-685782 
Fax: +94-1-685782 
E-mail:

 [email protected] 

Contact: Kithsiri De Silva 

Bosö Motor AB 
Box 6053 
181 06 Lidingö 

SWEDEN

 

Tel: +46-876-71940 
Fax: +46-873-17169 
E-mail:

 [email protected]

 

Contact: Robin Carlsson 

Marindiesel 
Blodboksgatan 26 
426 74 V. Frölunda 

SWEDEN

 

Tel: +46-31-293-058 
Fax: +46-31-694-111 

Min Sen Machinery Co, Ltd 
777 Mahachai Road 
Wangburapapirom 
Pranakorn Bangkok 10200 

THAILAND 

Tel: +66-2-6211000 
Fax: +66-2-6211049 / 2252877 
E-mail: 

[email protected]

 

Website: 

www.minsen.co.th

  

Contact: Tawee Techatonyanon 

GEPA Fiberglass 
Tersane Yolu, Yan Sanayi Bölgesi 
Aydintepe (P O Box 7) Tuzla 
81700  Istanbul 

TURKEY 

Tel: +90-216-392-9396 
Fax: +90-216-392-7758 / 2064 
E-mail: 

[email protected]

  

Website: 

www.gepafiberglass.com

  

Contact: Alp Özalp, President 

SOLAS Marine Services Co (L.L.C.) 
P O Box 25445 
Dubai 

UNITED ARAB EMIRATES 

Tel: +971-4-3241-700 
Fax: +971-4-3241-804 
E-mail: 

[email protected]

 

Contact: P S Kamath, S Prabhu 

Uruguayan Marine Safety Ltd 
Arturo Lezama 2228 
11800  Montevideo 

URUGUAY

 

Tel: +598-2-924-6025 
Fax: +598-2-924-4938 
E-mail: 

[email protected]

 

Website:

 www.ums.com.uy 

Contact: Alberto Zambrana 

North Jersey Marine 
215 Trimble Ave. 
Clifton, N.J. 07011 

USA

 

Tel: +1-973-667-1730 
Fax: +1-973-667-1831 
E-mail: 

[email protected]

 

Contact: Bob Bain 

Waterway Diesel Center Inc. 
P.O. Box 97 
Deale, Maryland 20751-0097 

USA

 

Tel: +1-410-867-2182 / +1-44-3871-6256 
Fax: +1-410-867-3366 
E-mail: 

[email protected]  

Contact: Davis H. Craven 

Alexander / Ryan Marine & Safety Co 
P O Box 9363 
Houston, Texas 77261-9363 

USA

 

Tel: +1-713-923-1671 
Fax: +1-713-923-1972 
E-mail: 

[email protected]

 

Website: 

www.alexanderryan.com

 

L.A. Maritime Services, Inc. 
327 Lecouvreur Avenue 
Los Angeles, CA 90744 

USA 

Tel: +1-310-518-1718 
Fax: +1-310-549-1122 
E-mail: 

[email protected]

 

Website: 

www.la-maritime.com

 

Contact: Sonia L. Brown 

 

 

 

 

Summary of Contents for DV36 RME

Page 1: ...009W4326 R08 OWNER S HANDBOOK FOR BUKH MARINE DIESEL LIFEBOAT ENGINE TYPE DV36 RME BUKH A S Aabenraavej 13 17 DK 6340 Krusaa Tel 45 74 62 20 88 Fax 45 74 62 74 07 E mail bukh bukh dk www bukh dk...

Page 2: ...of oil 7 Recommended lubricating oil 7 Change of lubricating oil filter 7 Cooling water system 7 Frost precautions 8 Electrical system 8 Marine gear 8 Starting instructions 8 Winter storage of the eng...

Page 3: ...rsible engine mountings 17 Lubricating oil filter 18 Dipstick for engine oil 19 Fuel pump 20 Control lever 21 Cock 22 Reverse reduction gear 23 Cooling water circulating pump 24 Exhaust pipe connectio...

Page 4: ...without previous notice Read this instruction book thoroughly before starting your new BUKH Diesel Engine STANDARD EQUIPMENT for DV36RME Reverse reduction gear Wet sump lubrication oil system Full fl...

Page 5: ...y the starter motor until fuel free from bubbles runs out from the fuel pressure pipes Finally tighten the pipes and the engine fuel system is ready for use This procedure must also be followed if the...

Page 6: ...e Stop button or pull the mechanical stop handle until engine stops 4 Move the Off Run switch to the Off position 5 Turn off the battery main switch Running in To secure long life and maximum power it...

Page 7: ...arious conditions Therefore use a first class HD oil from a recognized oil company Oil specifications as mentioned in LUBRICATION OIL CHART When operating under difficult conditions i e frequent cold...

Page 8: ...attery NOTE The starter must not be operated for more than 10 sec If further operation is necessary a pause of at least half a minute before starting attempt is repeated Marine Gear The engine is equi...

Page 9: ...y in a dry place during the winter 4A For freshwater cooled engines Drain the freshwater from the engine by removing the plugs as indicated for seawater cooled engines It is not necessary to flush thi...

Page 10: ...oil Consequently the oil will get too warm and foam and bleeding will be inadequate Oil vapour will condense and in extreme cases run out of the suction filter Do NOT fill the engine with more oil tha...

Page 11: ...aring housing Checking of oil level Dismount the filling plug with dipstick when the spray pump is in a horizontal position The oil level must be just above the lower edge of the shaft When turning th...

Page 12: ...TIMING AUTOMATIC VARIABLE FUEL LIFT PUMP CAM SHAFT DRIVEN DIAPHRAGM PUMP STATIC PRESSURE OF FUEL LIFT PUMP 153 285 mBar FUEL FILTER THROW AWAY FILTER INSERT FUEL QUALITY GAS OIL BS 2869 CLASS A LUBRI...

Page 13: ...X 4 Check of fuel system 4 1 supply line clean water fuel separator and check line bends repair if damaged or renew X 4 2 fuel tank drain for water X 4 3 fuel filter change X 4 4 return line check fo...

Page 14: ...RPM adjust RPM X 9 4 Full speed loaded with propeller and spray pump 2800 3600 RPM adjust RPM X 9 5 Cooling water temp to be max 95 degr Celcius max 95 C change termostat X 9 6 Audible and visual alar...

Page 15: ...r incorrectly adjusted or something in the system works sluggishly Adjust the governor Check governor system and correct the error Hot engine smell of heat Insufficient cooling water supply Stop engin...

Page 16: ...SAE 15W 40 API CG 4 FZG11 EXXON ESSO SPARTAN EP220 ISO VG 220 X EXXON ESSO GEAROIL GX SAE 80W 90 X MOBIL OIL MOBIL 1 0W 40 SAE 0W 40 API SJ CF EC X X X X MOBIL OIL MOBIL Delvac 1 SHC SAE 5W 40 API CE...

Page 17: ...OPERATING MANUAL FOR BUKH DV36RME LIFEBOAT ENGINES 009W4326 R08 17...

Page 18: ...OPERATING MANUAL FOR BUKH DV36RME LIFEBOAT ENGINES 009W4326 R08 18...

Page 19: ...OPERATING MANUAL FOR BUKH DV36RME LIFEBOAT ENGINES 009W4326 R08 19 Installation DV36...

Page 20: ...in Company Ltd Qinhuangdao Office No 1 11 Nongken Building Shanhaiguan Development Zone Hebai CHINA 066206 Tel 86 335 5082 500 Fax 86 335 5085 036 E mail forwin heinfo net For Win Equipment Engineerin...

Page 21: ...anvier Passero 06210 Mandelieu FRANCE Tel 33 4 92 19 50 89 Fax 33 4 93 47 65 11 E mail diams020 aol com Contact Raymond Allo Bukh Bremen GmbH Kornstrasse 243 28201 Bremen GERMANY Tel 49 421 535070 Fax...

Page 22: ...The Engine Room Limited 34 Enterprise Street P O Box 34 0132 North Shore City 0746 Auckland NEW ZEALAND Tel 64 9 480 2248 Fax 64 9 480 2258 E mail theengineroom xtra co nz Website www theengineroom c...

Page 23: ...n Machinery Co Ltd 777 Mahachai Road Wangburapapirom Pranakorn Bangkok 10200 THAILAND Tel 66 2 6211000 Fax 66 2 6211049 2252877 E mail tawee minsen co th Website www minsen co th Contact Tawee Techato...

Page 24: ...ected later than the stipulated settling date interest shall be paid on overdue payments at the rate of 1 5 per cent per month or fraction of a month Bukh A S reserves the right to change the rate of...

Reviews: