OPERATING MANUAL FOR BUKH DV29RME LIFEBOAT ENGINES
009W4926-R19
- 8 -
Frost precautions
As protection against corrosion and to secure the cooling water freezing temperature to min. minus 15° Celsius as per
IMO/SOLAS requirement or lower if required from climate conditions, It is recommended to use a mixture of
min. 30%
antifreeze liquid and 70% water
and
max. 50% antifreeze and 50% water.
However
please also note when doing service on lifeboats
that the mix of water and antifreeze can get aggressive and
start corrosion. If corrosion is found in the cooling system it can be caused by one of two conditions:
1. The anti corrosion additives in the anti freezing liquid are exhausted and have evaporated.
2. Oxidation due to incoming air causing an acid which is lowering the PH value.
Therefore and also to keep the anti freezing proporties it is recommended to
change the cooling water and antifreeze every
3 years min.
Please also note the details provided by your supplier of antifreeze liquid normally stated on the can.
Electrical System
The engine is equipped with a 12 volt electrical system consisting of a starter motor and an alternator, the max. charging
current of which is 50 Amp.
Electrical wiring diagram for the engine with control and instrument panels is shown later in this instruction.
The battery must never be isolated from the alternator, when the engine is running.
Warning! It is not allowed to connect additional equipment to the wiring system on the engine. Possible additional
equipment has to be connected directly to the terminals of the battery.
NOTE!
The starter must not be operated for more than 10 sec. If further operation is necessary a pause of at least half a minute
before starting attempt is repeated.
Marine Gear
The engine is equipped with a reverse-reduction gear.
The reduction is 3.06:1 for AHEAD and 2.44:1 for REVERSE.
The marine gear will need no other attendance than regular change
of oil. This to be carried out after 25 hours of operation, and then
every 500 hours or once a year.
Oil quality: "
Automatic Transmission Fluid” (ATF)..
The oil change is carried out by means of the lubricating oil bilge pump.
The oil should be warm when draining.
Refill new oil to the quantity of 0.4 liters through the dipstick hole.
Check oil level on the dipstick.
Starting instructions for BUKH Diesel Engine type DV29RME
Electric start:
1. Switch on the main switch.
2. Put the gear in neutral position
3.
Put the switch into ”RUN” position
4.
Push the ”START” button until the engine starts
Cold Start (below minus 15
o
C if mounted):
Start pilot: Pull and push the pump (2) 2-3 times.
Stopping the
engine: Push the ”STOP” button until the engine
stops.
After the engine has stopped:
Put the switch in ”OFF” position.
Filling the pressure tank (3) (if mounted):
1. Open the cover.
2. Put the gas cylinder on top of the valve and fill up the tank
to max. marking.
Hand Start: (If mounted):
Put gear into neutral position.
Put handle into crank claw.
Lift decompression lever (1).
Cold start with hand start (below 0
o
C).
Start pilot: Pos 1
– 2 - 3
Pull and push the pump (2) 2-3 times.
Turn the start handle as quickly as possible (clockwise), release the decompression lever, but keep on turning until the engine
starts.
Summary of Contents for DV29 RME