Servicing / Maintenance
26
6
Servicing / Maintenance
Danger!
Voltage hazard.
All operations which necessitate opening the device may be performed only by qualified
electricians.
Burn hazard!
Nozzle (1) and molten adhesive can be over 200 °C hot. Wear heat-resistant gloves
when performing servicing and maintenance operations.
6.1
Service intervals
Observe the stated service intervals to ensure always correct and reliable operation:
Daily:
Inspect and if necessary drain the service-unit water separator (see Fig. 6.1/1)
Check that all parts are present, leak-free and undamaged and all screws and lines securely
seated
Weekly:
Remove adhesive residues and other contaminants, especially on the inside of the cover
MAX
max. level
press to drain
Fig. 6.1/1:
Draining the water separator
6.2
Cleaning
• Do not use aggressive cleaning agents for cleaning the device. These may damage
device components.
We recommend cleaning with paraffin oil.
• Replace completely parts which are no longer cleanable (e.g. because of burnt-on or
reacted hot-melt adhesive). We recommend having this work done by the manufacturer
or distributor.
• Remove residues of hot-melt adhesive and other contaminants by mechanical means
only, e.g. with a cloth, soft brush, wooden spatula or similar.
GB