IECEx Certificate
of Conformity
Certificate No:
IECEx FMG 18.0005X
Issue No: 0
Date of Issue:
2018-10-04
Schedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
TC-Standard (+) (X2)
4496 21 abcdefghijklmno
a = Quanity of heat exchangers; 1 or 2
b = Operating temperature; 40°C or 50°C
c = application area
d = voltage; 3
e, f, g = Type of heat exchangers
h, i = Type and connection of peristaltic pumps
j, k = Type of humdity sensor and filter
l, m = Status output
n, o = Delta temperature; yes or no
TC-MIDI (+) (X2)
4496 31 abcdefghijklmno
a = Quanity of heat exchangers; 1 or 2
b = Operating temperature; 40°C or 60°C
c = Application area
d = Voltage; 2
e, f, g = Type of heat exchangers
h = Type peristaltic pumps
i = Type of gas pumps
j, k = Type of humidity sensor and filter
l, m = Status ouput
n, o = Delta temperature; yes or no
TC-Double (+) (X2)
Page 3 of 4