Voltages and currents
All Bühler level contacts with reed switch can switch minimal Switching voltages of 10 µV and minimal switching currents of
1 µA.
The maximum values specified for the respective contact types apply.
Level contact with reed switches can therefore be used for SPS applications as well as for high loads (within the maximum lim-
its) without hesitation.
Contact material
All reed switches in Bühler level contacts use rhodium as the contact material for the actual contact areas.
Magnetic fields
Avoid external magnetic fields, including from electric motors. These can interfere with the function of the reed switches.
Mechanical loads
Do not expose the level switch to strong blows or bending.