36
EVERY TWELVE MONTHS:
Refer to CB-1PR Exploded View Parts List. (Page 12)
1" Bearing with Fasteners Item # 21:
Do not grease the bearing it is greased for life by the
manufacturer. If the grease fitting has not been removed and plugged we suggest that you do so now.
Earlier models may not have been plugged at time of assembly.
1-1/4" Bearing with Fasteners Item # 22:
Do not grease the bearing it is greased for life by the
manufacturer. If the grease fitting has not been removed and plugged we suggest that you do so now.
Earlier models may not have been plugged at time of assembly.
P.M. Motor Assembly Item # 9:
Bodine gear motor lubrication. Fill gear motor to oil level indicator with
worm gear oil conforming to AGMA#5EP compounded (SAE#90) oil or Bodine lubricant #LO-23. Do not
overfill.
Transmission 3.5:1 Assembly Item # 8:
Inspect for excessive wear and tear. Keep the transmission
assembly clean and lubricate with Lubriplate #630-AA.
Refer to CB-1PR Wiring Diagram. (Page 14)
CB-1PR Collector:
The collector ring should be sanded once a year. If the collector ring is pitted too
badly it should be replaced. Inspect all wires coming out of the collector ring for cut or missing insulation.
All wires should be fastened to the center shaft with a nylon cable tie. Tighten four set screws if needed.
Manifold Power Cable:
Ensure that the cable is fastened tightly to the large brush holder and the
manifold retainer. Inspect the cable for cut or missing insulation. Replace the cable if necessary.
Manifold Retainer Item:
Inspect for damage. Ensure that all cables and the oxygen hose are fastened
tightly. Inspect the cables and oxygen hose for cuts or missing insulation. Replace if necessary.
Junction Box Item:
Inspect the cables for cuts or missing insulation. Ensure that all terminal ends and
connections are snug. Replace if necessary.
Low Frequency Power Cable:
Inspect the cable for cut or missing insulation. Ensure that the micarta
insulator is in good condition. Replace if necessary.
High Frequency Power Cable:
Inspect the cable for cut or missing insulation. Ensure that the micarta
insulator is in good condition. Replace if necessary.