Items
Descriptions
Network Information
Displays IP addresses, subnet masks, default gateways, and link
speed.
Drive
Displays the status, drive numbers, names, capacity, and physical
sector sizes of each drive.
Options
:
Shut down when the drive's temperature becomes abnormally
high
: The TeraStation will automatically shut down if the drive gets
too hot.
ERROR
Displays error or information codes. For more detail information, refer
to the "Errors and Statuses on Buffalo Dashboard" section below.
Note:
"Options" and "Check for updates" functionalities are only available when logged in as an administrator.
Errors and Statuses on Buffalo Dashboard
Message
Description
Corrective Action
SYSTEM Error E11
Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or another tool to remove them. If
the error is displayed again, contact Buffalo
technical support for assistance.
SYSTEM Error E12
Cooling Failure
A rise in the system temperature
may have exceeded the allowable
safety value.
Do not place objects in the area around
the TeraStation. Also, move the TeraStation
to a cool location. Make sure that the
TeraStation's fan is working normally.
HDx Error E16
HDx Not Found
Unable to find hard drive X.
Hard drive may be disconnected or may have
failed.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive
was removed from the RAID array.
Replace hard drive.
SYSTEM I10
TOO HOT !
A rise in the system temperature
may have exceeded the allowable
safety value.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
Operation I12
DEGRADE MODE
Operating in degraded mode.
Check the drive where the error occurred
and replace it with a new hard drive. For
replacing method, refer to the "Hard Drive
Replacement Procedure" section in chapter 6.
RAID I18
x Drive Rebuilding
Resynchronizing drive in the array.
Note:
Transfer speeds are slower
during the resynchronizing process.
Wait until the RAID resynchronization
finishes. It will take about 8–12 hours per
terabyte for a RAID 5 volume and 3–6 hours
per terabyte for a mirrored volume. This
message will disappear when the RAID
resynchronization finishes.
Replication I33
Replicate Failure
An error occurred during
replication.
From Buffalo Replication, click
Sync
to
execute resynchronization. If the error is
displayed again, contact Buffalo technical
support for assistance.
New Firmware I52
Available
A new firmware version has been
released.
Update the firmware.
16
Summary of Contents for TeraStation WSH5610
Page 26: ...6 Click Add Items 7 Select the backup source folders or drives and click OK 25...
Page 27: ...8 Click Next 26...
Page 28: ...9 Specify the schedule to run the backup and click Next 27...
Page 32: ...5 Select the date when a data backup occurred and click Next 31...
Page 38: ...2 Click Change 3 Select Domain enter a domain name and click OK 37...
Page 40: ...7 Click Close 8 Click Restart Now and restart your computer to apply settings 39...
Page 41: ...Installing DFS 1 In Server Manager click Dashboard Add roles and features 2 Click Next 40...
Page 42: ...3 Select Role based or feature based installation and click Next 4 Click Next 41...
Page 44: ...7 Click Next 8 Click Install 43...
Page 45: ...9 Click Close to finish Creating Namespaces 1 In Server Manager click Tools DFS Management 44...
Page 46: ...2 Click Namespaces New Namespace 3 Enter a hostname for the namespace server and click Next 45...
Page 47: ...4 Enter a name for the namespace and click Next 46...
Page 51: ...4 Select the type of replication group and click Next 50...
Page 52: ...5 Enter a name for the replication group and click Next 51...
Page 53: ...6 Enter the hostname of the file server for the replication source and click Next 52...
Page 54: ...7 Click Add 53...
Page 55: ...8 Enter the path of the replication source and click OK 54...
Page 56: ...9 Click Next 55...
Page 57: ...10Enter the hostname of the file server for the replication target and click Next 56...
Page 66: ...3 Right click Users and click New User 65...
Page 68: ...3 Double click Remote Desktop Users 4 Click Add 67...
Page 69: ...5 Click Advanced 6 Click Find Now 68...
Page 71: ...3 Right click Groups and choose New Group 4 Enter a group name and click Add 70...
Page 72: ...5 Click Advanced 6 Click Find Now 71...
Page 73: ...7 Select the users to be registered to the group then click OK 8 Click OK 72...