background image

PS07569 Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions Manual 

4

 

Disconnect the tool from power source before making any adjustments, storing, servicing, or 
changing accessories. This will reduce the risk of starting the tool accidentally. 
 
Do not force tool. Use the correct tool for your application. The correct tool will do the job better and 
safer at the rate for which it was designed. 
 

 

 

Do not use the tool if the switch does not turn it on and off. Any tool that cannot be controlled with the 
switch is dangerous and must be repaired. 
 
Check for damage. Check your tool regularly. If part of the tool is damaged it should be carefully 
inspected to make sure that it can perform its' intended function correctly. If in doubt, the part should be 
repaired. Refer all servicing to a qualified technician. Consult your dealer for advice. 
 
Keep away from flammables. Do not attempt to operate this tool near flammable materials or 
combustibles. Failure to comply may cause serious injury or death. 
 
Store idle tools out of the reach of children and untrained persons. Tools may be dangerous in the 
hands of untrained users. 
 
Maintain tools with care. Keep tools sharp and clean. Properly maintained tools, with sharp cutting 
edges, are less likely to bind and are easier to control. 
 
Never exceed the pressure rating of any component in system. 
 
Protect material and air lines from damage or puncture. Keep hose and power cable away from 
sharp objects, moisture, chemicals, oil, etc.  
 
Check condition of hoses before each use. Do not use a damaged hose. If hose is damaged, replace 
immediately. 
 
Read, understand and comply with all warning labels on unit. 

 

Keep harmful arc rays shielded from the view of others. 
 
Mount the plasma cutter on a secure bench or cart that will keep the welder secure and prevent it from 
tipping over or falling. 

 

Check all cables, power cord and torch to be sure the insulation is not damaged. Always replace or 
repair damaged components before using the plasma cutter. 
 
Check all components to ensure they are clean and in good operating condition before use. 
 
Do not operate the plasma cutter if the torch is wet. Do not immerse the plasma torch. Do not stand in 
water while using this plasma cutter. These components and the plasma cutter must be completely dry 
before attempting to use it. 
 
Keep the plasma cutter in the off position when not in use. 
 
Connect ground lead as close to the area being cut as possible to ensure a good ground. 
 
Do not allow any body part to come in contact with the material being cut, or to the ground or electrode 
from another plasma cutter or welder. 
 
Do not cut if you are in an awkward position. Always have a secure stance while cutting to prevent 
accidents. Wear a safety harness if working above ground. 

Summary of Contents for PS07569 Plasma 375

Page 1: ...hange this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT HAVE QUESTIONS OR PROBLEMS DO NOT RETURN THIS PRODUCT TO THE RETAILER CONTACT CUSTOMER SERVICE If you experience a problem or need parts for this product visit our website http www buffalotools com or call our customer help line at 1 888 287 6981 Monday Fr...

Page 2: ...t is used in order to allow power flow in the ON state and to stop flow when it is in the OFF state Works by applying voltage to a semiconductor component therefore changing its properties to block or create an electrical path This product contains chemicals known to the State of California to cause cancer and birth efects or other reproductive harm KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRAN...

Page 3: ...ng loose clothing or jewelry Keep long hair pulled back and away from moving parts Overreaching or have improper footing Handling the tool in this way could cause serious injury Wear the proper safety equipment such as safety goggles dust masks non skid shoes etc Check to be sure all adjusting keys or wrenches have been removed before use Safety glasses and ear protection must be worn during opera...

Page 4: ...ontrol Never exceed the pressure rating of any component in system Protect material and air lines from damage or puncture Keep hose and power cable away from sharp objects moisture chemicals oil etc Check condition of hoses before each use Do not use a damaged hose If hose is damaged replace immediately Read understand and comply with all warning labels on unit Keep harmful arc rays shielded from ...

Page 5: ...re when cutting Gas Pressure Adjustor It is used for adjusting the gas pressure The gas pressure can be read from the gas pressure display on the front panel Normally the pressure should be adjusted between 55 90psi When cutting this light is on to show the unit is on working mode Cutting Current Adjustor Variable adjust the output cutting current The higher output matches the thicker metal The ma...

Page 6: ... phase 230 220 240V 60HZ fused with a 50 amp time delayed fuse or circuit breaker is required DO NOT OPERATE THIS UNIT if the ACTUAL power source voltage is less than 170 volts AC or greater than 250 volts AC High voltage danger from power source Consult a qualified electrician for proper installation of receptacle This cutter must be Grounded while in use to protect the operator from electrical s...

Page 7: ...e no less than 50 PSI the Low Pressure Indicator Light will not be lit up in those conditions Adjust the air flow to be sure it is consistent Pull the torch trigger The cutting operation begins after the cutting plasma pilot arc is made Metal Sheet Cutting Put the torch s nozzle at the start of the work piece Turn on the torch switch to ignite the plasma pilot After the work piece is cut thorough ...

Page 8: ... doctor The magnetic field produced by plasma cutters during operation can disrupt pacemakers and similar devices Never clean the slag off the torch head by hitting it against a hard object SERVICE Tool service must be performed only by qualified repair personnel Service or maintenance by unqualified personnel could result in a risk of injury When servicing a tool use only identical replacement pa...