PS07569 Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions Manual
5
Do not drape cables over or around your body.
Wear eye protection (see ANSI Z49.1 safety standard) while cutting to protect your eyes from harmful
UV and IR ray’s.
Wear proper gloves and protective clothing to prevent your skin from being exposed to hot metals, UV
and IR rays.
Do not overuse or overheat your plasma cutter. Allow proper cooling time between duty cycles.
Keep hands and fingers away from moving parts.
Do not point the Plasma torch at any body part or at anyone else.
Always use this plasma cutter in the rated duty cycle to prevent excessive heat and failure.
DESCRIPTION
Plasma cutting equipment produces fumes or gases which contain chemicals known to the state
of California to cause birth defects and, in some cases, cancer. (California Health & Safety code
section 25249.5 et seq.)
Gas Pressure Display
The built-in gas display is used for reading the output gas pressure when cutting.
Gas Pressure Adjustor
It is used for adjusting the gas pressure. The gas pressure can be read from the gas pressure display
on the front panel. Normally, the pressure should be adjusted between 55-90psi. When cutting, this
light is on to show the unit is on working mode.
Cutting Current Adjustor
Variable adjust the output cutting current. The higher output matches the thicker metal. The maximum
cutting thickness is up to 3/8″ for this unit. Please note that the maximum cutting thickness varies
depending on the material type you are cutting.
Low Gas Indicator Light
This light will be on when the gas flow is low.
Ground Cable Connection
Connect the ground cable to the postive (+) receptacle on the front of the plasma cutter. The ground
cable clamp connects to your work piece.
Torch Control Cable Connection
The black cable on the torch connects to the 3-Prong receptacle on the front of the machine. Push on
to snap in place. This is the control cable for the torch.
Torch Arc Starting Cable Connection
This connector is for the red cable of the torch. It is used to help the arc starting.
Torch Connection
Connect the torch to the negative (-) receptacle.