6
Fitting the mounting bracket
SKR6.1R, SKR12.1R - Subject to technical modifications.
16
6.3
Installing mounting brackets on
plain tile roofs
B
Depending on the distances determined (
Æ
page 14)
remove 2-3 plain tiles from a row in the area of the
rafters.
B
Position the mounting bracket:
– The mounting bracket [1] must be installed in the
middle of the plain tile below.
– The mounting bracket must be installed directly
above the plan tile below it without touching this tile.
B
To make room for the mounting bracket, shorten the
plain tile at the top edge if necessary and/or make a
create a suitable fixing point to the roof.
B
Mark the mounting bracket positions on the roof.
B
Pre-drill rafter with 6 mm drill bit.
B
If required, use wooden spacer [4] supplied for height
compensation (pre-drill 9 mm).
B
Screw mounting bracket with 3 screws 8 x 120 mm [2]
onto the rafter. Use a SW13 spanner.
B
Cut adjacent plain tiles [3] and re-install them.
Fig. 22 Mounting brackets for plain tile roofs
1
Mounting bracket
2
Screws 8 x 120 mm
3
Plain tiles, trimmed
4
Wooden spacer 100 x 150 x 8 mm
NOTICE:
Roof leaks on plain tile roofs!
B
Consult a roofing contractor for advice
and assistance.
NOTICE:
Roof leaks from fine, wind-driven
snow in the area of the mounting bracket.
B
If there is a larger gap between the top
and the bottom roof tiles, close this gap
using UV-resistant sealant.
6720646203-11.1ST
2.
3.
3
1.
1
4
13
6
9
2