13
Maintenance/inspection
SKR6.1R, SKR12.1R - Subject to technical modifications.
31
13
Maintenance/inspection
The collector array must be checked at regular intervals
(inspection). Defects/faults must be remedied without
delay (maintenance). We recommend conducting the first
maintenance/inspection after about 500 hours run, and
then at intervals of 1-2 years.
Use the table as a copy template so that you will have
documentation available even after the third maintenance.
B
Fill out the report and tick off the tasks performed.
DANGER:
Risk to life through falls and
falling parts!
B
For all work on the roof, take appropriate
measures to prevent accidents.
B
Secure the roof against falls.
B
Always wear your own protective clothing
or safety equipment.
Owner:
Site location:
Maintenance and inspection tasks
Page
Maintenance/inspection
Date
1.
Visual inspection of the collectors carried out
(correct seating of glass tubes, visual impression)?
2.
Collector sensor is positioned correctly and is inserted into
the sensor well as far as it will go?
3.
Visual inspection of the installation system carried out?
4.
Visual inspection for leaks carried out at points where the
mounting system meets the roof?
5.
Visual inspection of pipe insulation carried out?
Notes
The collector array has been serviced as specified by these
instructions.
Date, stamp,
signature
Date, stamp,
signature
Date, stamp,
signature
Tab. 16 Inspection and service report