2
Product information
SKR6.1R, SKR12.1R - Subject to technical modifications.
7
2.4.3
Connection sets (hydraulic connection)
Fig. 6
Standard delivery, connection set, rooftop
2.4.4
Collector
Fig. 7
Collector with pre-assembled male connectors
2.5
Data plate
The data plate is mounted on the header box and contains
all important information in the form of symbols.
Item 1
Cap, thermal insulation
1 x
Item 2
Installation and maintenance
instructions
1 x
Item 3
Return feed bend
1 x
Item 4
Connection pipe, fully assembled
(incl. corrugated stainless steel pipe,
thermal insulation and 18 mm locking
ring fitting for connection to the
common pipeline)
2 x
Item 5
Reducer 18 x 15 mm
2 x
Tab. 5
Standard delivery, connection set, rooftop
Item 1
Male connectors to join the collectors
2 x
Item 2
Collector SKR6.1R/SKR12.1R
comprising: vacuum tubes,
CPC mirror and header box
1 x
Tab. 6
Standard delivery, collector
6720648182-02.1ST
5
6 720 647 042-08.1ITL
Symbol
Meaning
Explanation
A
G
area
gross
Gross area
A
a
area
aperture
Aperture area
A
A
area
absorber
Absorber area
Dimensions
Measurements
V
f
volume
fluid
Collector contents
m
mass
Weight
t
stg
temperature
stagnation
Stagnation
temperature, max.
p
max
pressure
maximum
Max. operating
pressure
p
pr
pressure
test
Test pressure
y
prod
year
production
Year of manufacture
Tab. 7
Data plate information