Tank Installation
6
6
Tank Installation
6.1
Placement of the Tank
The tank is designed for horizontal installation and can
serve as base for a Buderus boiler.
For placement of the tank, observe the recommended
clearance dimensions for proper access and service.
(Fig. 8). Buderus requires maintaining a minimum
clearance of 2" between hot water piping and
combustible surfaces.
Make sure that the floor is level and sufficiently strong.
The tank can be installed on combustible flooring as
long as the screw-in feet are used.
Level the tank using the adjustable feet (Fig 9).
Fig. 8
Placement of tank (Recommended clearances)
mi
n.
26 i
n
.
min.
16 in.
CAUTION!
TANK DAMAGE
Due to frost.
Make sure that the boiler room is dry
and frost free.
Fig. 9
Leveling of the tank using a level
NOTICE
The screw-in feet have rubber feet that
allows you to slide the tank in its final
location.