Other Risks 

 

Have you checked that there are no ongoing processes in the area (eg 

below the roof you’re working on) that may be dangerous – X-ray 

machines, other radiation? 

 

Are you certain that the instrument has not been immersed, dropped or 

otherwise damaged in a way that is not obvious?  

 

Have you verified that the ground connection is actually grounded?   

 

Is the person responsible for site safety aware of / fully understanding the 

testing you are going to do, and has it been reviewed in line with the site 

procedures? 

 
 

Maintenance 

The PST-100 has been designed to be maintenance free, however the PST-100 

should be inspected regularly, checking for damage to the unit. If any damage is 

found, the PST-100 must not be used, and should be returned to the manufacturer 

for repair. 
Two 500mA anti-surge fuses are located on the rear panel. These may be replaced 

by the user. Disconnect the PST-100 from the mains supply before attempting to 

replace fuses. 

 

Disposal information 

Producer registration number: WEE/HJ0051TQ

 

This Product must be disposed of in accordance with UK WEEE 

Producer Responsibility Regulations, or in accordance with your local 

WEEE guidance.

 

For further information on UK 

WEEE 

Producer Responsibility 

regulations click on: 

http://www.gov.uk/government/collections/producer

-responsibility-regulations 

IMPORTANT: 

Service and repair of this product and its components 

MUST ONLY

 

be undertaken by trained, approved technicians working in full accordance 

with Buckleys’ service guidelines. Failure to do so may expose the operator to 

potentially lethal voltages.  

Under no circumstances

 should anyone other than trained approved 

technicians attempt to dismantle or repair this product. 

NOTE: 

Wherever you are intending to use equipment of this type, on your site or on a 

customer’s, always obtain clearance from the company safety officer. 

Summary of Contents for PST-100

Page 1: ...PST 100 High Voltage Spark Tester Instruction manual Please read this manual before using the equipment 5830 0012 07 21 English...

Page 2: ......

Page 3: ...ating the test voltage 9 SP 02 74 test voltage formula 9 Operation 10 Setting the Output Voltage 10 Applications 11 Insulation Testing 11 Gas Discharge Lamp Testing 11 Ozone Production 11 Risk Assessm...

Page 4: ...or flaws in electrically non conductive coatings linings membranes pipe wraps and other plastic coated metals The PST 100 generates a pulsed ring output voltage The pulse repetition is 20mS 50Hz or 16...

Page 5: ...0007 6000 0015 105 120V AC Supply frequency 50 to 60 Hz Max power consumption 30VA Output voltage 10kV to 55kV Output Pulsed Ring Pistol weight 1 0kg Altitude Up to 2000m Relative humidity 80 Max Non...

Page 6: ...sed by responsible and authorised personnel that have read and understood this manual The probe must NEVER be directed at the body There is a potential risk to those who might have an incipient heart...

Page 7: ...handle is a functional earth terminal NOT a Protective Conductor Terminal as defined by IEC61010 and is intended as a high voltage return point during the operation of the PST 100 This arrangement als...

Page 8: ...to a point of a measuring or control circuit or to a screening part and which is intended to be earthed for any functional purpose other than safety Double Insulation Insulation comprising both basic...

Page 9: ...spark then forms ionising the air drastically reducing its electrical resistance For materials with a thickness in the range of 1mm to 30mm the NACE Standard SP 02 74 voltage calculation formula is no...

Page 10: ...be kept moving when testing as the high voltage and ring frequency combination may cause heating in the article under test which may result in burning The output control should be adjusted for the lo...

Page 11: ...probe discharge will change to a single spark Remove the probe from the surface and mark the point where the fault was detected Gas Discharge Lamp Testing The PST 100 can be used to excite gas dischar...

Page 12: ...rks is the test outdoors or is there sufficient suitable ventilation in place to ensure that this is not hazardous Is the access route to the area of the test safe Is fall protection necessary If so i...

Page 13: ...the rear panel These may be replaced by the user Disconnect the PST 100 from the mains supply before attempting to replace fuses Disposal information Producer registration number WEE HJ0051TQ This Pr...

Page 14: ...CEO Buckleys UVRAL Ltd UKCA Declaration of conformity We Buckleys UVRAL Ltd as sole manufacturer of the apparatus listed below declare that the product PST 100 High Voltage Spark Tester is manufactur...

Page 15: ...nufacturer Buckleys UVRAL Ltd Address Buckleys House Unit G Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG UK Tel 44 0 1303 278888 Website www buckleysinternational com Di...

Page 16: ...ng to your product Be the first to hear about our new products We strive to improve the quality of our products and service Registering your product helps us monitor overall quality of our products se...

Reviews: