Risk Assessment 

It the user’s responsibility to complete a risk assessment before using Buckleys 

equipment.  The following points offer some guidance but must not be assumed to 

be complete or sufficient. 

Personal safety  

 

Have all users been trained in the correct and safe use of the instruments?   

 

Are they aware that the instrument produces high voltages, and can give 

electric shocks if used incorrectly?   

 

Is the instrument in good condition, undamaged?  Is the instrument dry?  

Are the accessories similarly in good condition, dry and undamaged? 

 

Is it possible to ensure that persons with pacemakers, cochlear implants or 

trans-dermal implants of any kind are sufficiently far from the instrument & 

test site to be safe?   

 

Ozone is an irritant gas which will be produced when the instrument 

produces sparks – is the test outdoors, or is there sufficient, suitable 

ventilation in place to ensure that this is not hazardous? 

 

Is the access route to the area of the test safe?  Is fall protection 

necessary?  If so, is it in place? 

 

Has the instrument been properly grounded to a metallic grounding point? 

Explosion & Fire Risk 

 

Buckleys high-voltage instruments will produce sparks - Are you certain that 

there is no risk of an explosive atmosphere?   

 

Have all easily-ignited and/or flammable materials been removed from 

the area to be tested? 

EMC & RFI 

 

Buckleys high-voltage instruments will produce sparks which may create 

interference in nearby electronic apparatus, particularly communication 

and computer equipment. 

 

Are you certain that there is no risk of such interference causing a danger 

to others – particularly medical or life support equipment?   

 

Are you sure that there is no risk of such interference causing costs or 

inconvenience to others – eg industrial processes, measuring equipment, 

scientific apparatus, domestic radio and TV?   

 

 

 

Summary of Contents for PST-100

Page 1: ...PST 100 High Voltage Spark Tester Instruction manual Please read this manual before using the equipment 5830 0012 07 21 English...

Page 2: ......

Page 3: ...ating the test voltage 9 SP 02 74 test voltage formula 9 Operation 10 Setting the Output Voltage 10 Applications 11 Insulation Testing 11 Gas Discharge Lamp Testing 11 Ozone Production 11 Risk Assessm...

Page 4: ...or flaws in electrically non conductive coatings linings membranes pipe wraps and other plastic coated metals The PST 100 generates a pulsed ring output voltage The pulse repetition is 20mS 50Hz or 16...

Page 5: ...0007 6000 0015 105 120V AC Supply frequency 50 to 60 Hz Max power consumption 30VA Output voltage 10kV to 55kV Output Pulsed Ring Pistol weight 1 0kg Altitude Up to 2000m Relative humidity 80 Max Non...

Page 6: ...sed by responsible and authorised personnel that have read and understood this manual The probe must NEVER be directed at the body There is a potential risk to those who might have an incipient heart...

Page 7: ...handle is a functional earth terminal NOT a Protective Conductor Terminal as defined by IEC61010 and is intended as a high voltage return point during the operation of the PST 100 This arrangement als...

Page 8: ...to a point of a measuring or control circuit or to a screening part and which is intended to be earthed for any functional purpose other than safety Double Insulation Insulation comprising both basic...

Page 9: ...spark then forms ionising the air drastically reducing its electrical resistance For materials with a thickness in the range of 1mm to 30mm the NACE Standard SP 02 74 voltage calculation formula is no...

Page 10: ...be kept moving when testing as the high voltage and ring frequency combination may cause heating in the article under test which may result in burning The output control should be adjusted for the lo...

Page 11: ...probe discharge will change to a single spark Remove the probe from the surface and mark the point where the fault was detected Gas Discharge Lamp Testing The PST 100 can be used to excite gas dischar...

Page 12: ...rks is the test outdoors or is there sufficient suitable ventilation in place to ensure that this is not hazardous Is the access route to the area of the test safe Is fall protection necessary If so i...

Page 13: ...the rear panel These may be replaced by the user Disconnect the PST 100 from the mains supply before attempting to replace fuses Disposal information Producer registration number WEE HJ0051TQ This Pr...

Page 14: ...CEO Buckleys UVRAL Ltd UKCA Declaration of conformity We Buckleys UVRAL Ltd as sole manufacturer of the apparatus listed below declare that the product PST 100 High Voltage Spark Tester is manufactur...

Page 15: ...nufacturer Buckleys UVRAL Ltd Address Buckleys House Unit G Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG UK Tel 44 0 1303 278888 Website www buckleysinternational com Di...

Page 16: ...ng to your product Be the first to hear about our new products We strive to improve the quality of our products and service Registering your product helps us monitor overall quality of our products se...

Reviews: