Buckleys PST-100 Instruction Manual Download Page 1

 

 

PST-100 

High Voltage Spark Tester 

Instruction manual 

Please read this manual before using the equipment 

 

 

 
 

5830-0012 07

/21 │ English

Summary of Contents for PST-100

Page 1: ...PST 100 High Voltage Spark Tester Instruction manual Please read this manual before using the equipment 5830 0012 07 21 English...

Page 2: ......

Page 3: ...ating the test voltage 9 SP 02 74 test voltage formula 9 Operation 10 Setting the Output Voltage 10 Applications 11 Insulation Testing 11 Gas Discharge Lamp Testing 11 Ozone Production 11 Risk Assessm...

Page 4: ...or flaws in electrically non conductive coatings linings membranes pipe wraps and other plastic coated metals The PST 100 generates a pulsed ring output voltage The pulse repetition is 20mS 50Hz or 16...

Page 5: ...0007 6000 0015 105 120V AC Supply frequency 50 to 60 Hz Max power consumption 30VA Output voltage 10kV to 55kV Output Pulsed Ring Pistol weight 1 0kg Altitude Up to 2000m Relative humidity 80 Max Non...

Page 6: ...sed by responsible and authorised personnel that have read and understood this manual The probe must NEVER be directed at the body There is a potential risk to those who might have an incipient heart...

Page 7: ...handle is a functional earth terminal NOT a Protective Conductor Terminal as defined by IEC61010 and is intended as a high voltage return point during the operation of the PST 100 This arrangement als...

Page 8: ...to a point of a measuring or control circuit or to a screening part and which is intended to be earthed for any functional purpose other than safety Double Insulation Insulation comprising both basic...

Page 9: ...spark then forms ionising the air drastically reducing its electrical resistance For materials with a thickness in the range of 1mm to 30mm the NACE Standard SP 02 74 voltage calculation formula is no...

Page 10: ...be kept moving when testing as the high voltage and ring frequency combination may cause heating in the article under test which may result in burning The output control should be adjusted for the lo...

Page 11: ...probe discharge will change to a single spark Remove the probe from the surface and mark the point where the fault was detected Gas Discharge Lamp Testing The PST 100 can be used to excite gas dischar...

Page 12: ...rks is the test outdoors or is there sufficient suitable ventilation in place to ensure that this is not hazardous Is the access route to the area of the test safe Is fall protection necessary If so i...

Page 13: ...the rear panel These may be replaced by the user Disconnect the PST 100 from the mains supply before attempting to replace fuses Disposal information Producer registration number WEE HJ0051TQ This Pr...

Page 14: ...CEO Buckleys UVRAL Ltd UKCA Declaration of conformity We Buckleys UVRAL Ltd as sole manufacturer of the apparatus listed below declare that the product PST 100 High Voltage Spark Tester is manufactur...

Page 15: ...nufacturer Buckleys UVRAL Ltd Address Buckleys House Unit G Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG UK Tel 44 0 1303 278888 Website www buckleysinternational com Di...

Page 16: ...ng to your product Be the first to hear about our new products We strive to improve the quality of our products and service Registering your product helps us monitor overall quality of our products se...

Reviews: