Draught copy needs finishing
www.oilstoves.co.uk
BELFORT MARINE OIL STOVE ©
INSTALLER INSTRUCTIONS ISSUE 2 @08-02-03
Page 1: ...Draught copy needs finishing www oilstoves co uk BELFORT MARINE OIL STOVE INSTALLER INSTRUCTIONS ISSUE 2 08 02 03...
Page 2: ...TRIM 8 TANK 8 OIL LINE 8 WATER CONTAMINATION 8 REMOTE SENSING FIREVALVE 9 ISOLATION VALVES 9 SLEEVING 9 5 FIREPLACE 9 6 FITTING DRY STOVES 9 SELECT LOCATION 9 FIT OIL TANK 9 RUN OIL LINE 9 TRIAL FIRE...
Page 3: ...AIR LOCKED SYSTEM PIPEWORK 14 INADEQUATE SYSTEM PRESSURE HEAD 14 INOPERATIVE CIRCULATING PUMP 14 INADEQUATE PIPE SIZEING 14 INADEQUATE CALORIFYER DESIGN 14 INADEQUATE STOVE LOCATION 14 FLOW OF WATER...
Page 4: ...R GLASS 16 LABOUR COSTS 16 TRAVELING COSTS 16 CONSEQUENTIAL LOSS 16 CONSEQUENTIAL DAMAGE 16 If you have any difficulties please phone our technical help line on 01302 742520 fax 01302 750573 E mail sa...
Page 5: ...glass front door opened or cracked or without the lighting port plug fitted 8 The door glass may require light cleaning occasionally depending upon the continuous running time of the stove 9 The stov...
Page 6: ...rom the oil control valve 8 With the increased flow of oil extra heat is generated which in turn stimulates the chimney to work harder and consequently draw more air into the pot to maintain an adequa...
Page 7: ...the excess oil as per instructions in the faultfinding section The stove must be securely fastened down so that it can resist impact or collision and it must be level in both directions The stove must...
Page 8: ...inimum pressure head of out 8 is required This head is measured from the base of the oil tank to the top of the oil control valve In some cases this head can be affected by the ballast or trim of the...
Page 9: ...eeve must be fitted and sealed with a suitable sealant 5 5 F FI IR RE EP PL LA AC CE E Try to use materials which are easy to keep clean and fireproof such as tiles asbestolux or vermiculite boarding...
Page 10: ...PLATE FIT DECK FLANGE If you are going to use a standard deck flange for 6 inch extensions you will have to cut off the lower extension with a grinder to allow fitting of the fire stop spacer The dec...
Page 11: ...ake sure that the vertical sides of the fireplace can easily accommodate the pipe work When installing water heating Bubble stoves the space heating output will be reduced The boiler is high water con...
Page 12: ...y as to make it easily replaceable this means lock shielded valves at either side and easy access 7 7 C CO OM MM MI IS SS SI IO ON NI IN NG G If the stove has been fitted to an existing heating system...
Page 13: ...d stabilising procedure COMMISSIONING THE HIGH AND LOW FIRE There are two types of valve fitted to Bubble stoves and access to the low fire adjustment is different On the OCI ships valve the plastic d...
Page 14: ...1 Turn off the oil flow until the burner has settled down to a steady burn rate and then turn the fuel on again but don t let the flame go out otherwise the burner MUST be allowed to cool down fully...
Page 15: ...ag into the stove and sponge from the pot into the bag when the excess oil has been removed put the plastic bag and sponge into another plastic bag and dispose of it 8 OPERATING OIL FLOW RATES OIL Flo...
Page 16: ...rranty form and returned it to us the information recorded on the warranty form helps us to deal with any problems you may encounter Where we do not hold returned warranty forms replacement parts woul...
Page 17: ...15...
Page 18: ...16...
Page 19: ...17...
Page 20: ...wledged that due to this process there may be some omissions and errors This publication is intended only to assist the reader in the use of this product and therefore Harworth Heating Ltd shall not b...