Technical Data and Installation
WINDINGFEEDER
- 2.1 -
2 – TECHNICAL DATA AND INSTALLATION
Technical Features
WINDINGFEEDER Device
Power supply voltage
24 VDC ± 10% or 24 VAC ± 20%
0.2 A
(during normal operation);
1 A
(under stress);
Maximum absorption
3 A
(at start-up)
STOP Outputs: relay contacts (NO)
0.3 A 125 VAC
1 A 30 VDC
Opto-insulated Inputs
0-24 VDC
VIL Max 1.2 VDC
VIH Min 5 VDC
Max. voltage
Iinputs,- Output)
30
VDC
Programmable yarn tension
0.5
÷ 100.0 gr. (resolution 0.1 gr.) or
5 ÷ 1,000 gr. (resolution 1 gr.)
Depending on the type of TS44 sensor used
Programmable alarms
0.1 ÷ 10 sec.
Integrated keypad
3 push-b STOP red LED
Signaling
With LCD graphic display
Dimensions
290 x 86 x 94 mm
Operating temperature range
10° - 60 °C
Storage temperature
-25° - +85° C
Tension range
0 / full scale
Useful tension range
0% - 95% full scale
Max applicable tension
10 times the full scale value
IS3x/TS Sensor
Power supply voltage
12 .. 24 Vdc ± 20%
Absorption 15
mA
(max 20 mA)
STOP output
NPN
STOP output protection
Protection against over-voltages/short-
circuits
Maximum Current of STOP output
200 mA continuous; 500 mA peack
Reaction Delay
Programmable from 5 to 1,000 msec
Sensitivity
Programmable
(10 levels)
Signaling
With integrated LEDs
Dimensions
(mm)
15 x 15 x 36,5
(Narrow) -
25 x 15 x 36.5
(Wide)
Operating temperature range
10° - 60 °C
Storage temperature
-25° - +85° C
TS44/xxxyRW Sensor
Power supply voltage
12 .. 24 Vdc ± 10%
Absorption 20
mA
(max)
Analogue Output
100 mV - 10V
Analogue output resistance
1K Ohm
Operating temperature range
10° - 50 °C
Storage temperature
-25° - +85° C
Tension range
0 - fondo scala
Useful tension range
0% - 95% fondo scala
Max applicable tension
10 volte il fondo scala
Drift error (a)
0.05% / °C
Repeatability error (b)
0.5%
Max linearity error (c)
2% (0 - fondo scala)
Signaling
Mediante LED integrati
Dimensions
50 x 25 x 12.5 mm
Summary of Contents for WINDINGFEEDER
Page 1: ...WINDINGFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 2 0 March 2011 ...
Page 4: ...Table of Contents ii WINDINGFEEDER Page intentionally left blank ...
Page 19: ...Technical Data and Installation WINDINGFEEDER 2 5 WINDINGFEEDER overall dimensions in mm ...
Page 22: ...Technical Data and Installation 2 8 WINDINGFEEDER Page intentionally left blank ...
Page 42: ...Operation 3 20 WINDINGFEEDER Page intentionally left blank ...