![background image](http://html1.mh-extra.com/html/bticino/391695/391695_instruction-manual_2825490015.webp)
15
2. INSTALLATION
2.1 DIP Switch Setup (391695/391715/391716/391717 models)
Before installing the camera, set up the DIP switch to configure the camera ID and the communication protocol.
ON
ON
1
2
3
4
5
6
7
8
Camera ID Setup
ID numbers of cameras are set up with binary numbers. See the examples shown below.
Pin
1
2
3
4
5
6
7
8
Binary Value
1
2
4
8
16
32
64
128
Ex : ID=5
on
off
on off off off off off
Ex : ID=10
off
on
off on off off off off
The camera ID range is “1~255”.
Camera ID must not be “0”!
The factory default of the camera ID is “1”.
Match the camera ID with the Cam ID setting of your DVR or Controller to control the camera.
If you are connecting a single camera to a controller, terminate the camera. When connecting more than one camera to a
single controller, terminate the last camera on the communication line. The last camera means the camera farthest in cable
length from the controller.
Note that the total length of the communication cable between a controller and the camera(s) on the same communication
line must be less than 1.2Km.