Duration of activation 

1

1 minute

2

2 minutes

3

3 minutes

4

4 minutes

5

5 minutes

6

15 minutes

7

30 seconds

8

0.5 seconds

CONFIGURATION

10

The basic radio actuator can be used in both a traditional system and a

 

My Home system. 

In both cases it must be first configured and then programmed.
The basic radio actuator can be controlled by radio control devices such as remote control item 3527, transmitting radio interface 
L/N/NT4576N, HC/HS4576 and radio control item H/L4572.
For the external contact which may be connected to the actuator a mode of operation can be chosen from those listed in the table 
below. The mode of operation for the external contact is determined by the type of configurator in socket M.

When used in a traditional system

, the sockets of configurators A, PL and G are not used.

When used in a My Home system

, transmitting radio interface item L/N/NT4576N must be installed and the actuator must be 

configured putting the correct configurators in the sockets of configurators A, PL, M and G. The actuator performs all the basic 
modes of operation which can be configured directly on the radio control devices, apart from those which require the use of two 
interlocked relays.
For details of the configuration refer to the following tables.

Description

Combination configurator in M

and type of external contact

Pushbutton

Switch

ON/OFF cyclical

No configurator

Monostable mode. (If installed 
in  a  My  Home  system  the 
actuator ignores the Area and 
General commands)

PUL

ON/OFF  mode.  Variations 
on the fronts (toggle)

O/I

Timed ON *

1÷8

The table lists the modes of operation with the configurator 
in position M:

*  If  controlled  by  external  pushbutton  the 
device switches off after a time established by 
the configurator in M, as indicated in the table.

The configuration operations must be performed with the actuator switched OFF.

11

PROGRAMMING

1.  Switch on the device.

2.  Keep the local key pressed until the LED lights up (about 4 seconds).

3.  Release the key.

4.  Within 20 seconds send the signal from the radio control device to be programmed.

 

Example:

 For remote control item 3527 press the key to be associated with the actuator.

5.  The LED flashes and then goes out, indicating that programming has taken place.

6.  Repeat the sequence of operations from point 2 to point 5 for all the radio control devices to be programmed (max 16).

12

CANCELLING

This operation cancels all the radio control devices previously programmed in the actuator.

1.  Switch on the device.
2.  Keep the local key pressed; after 4 seconds the LED lights up, keep the key pressed until the LED goes out.
3.  Release the key.
4.  The LED flashes and then goes out, indicating that all the radio control devices previously programmed in the actuator have been 

cancelled.

Summary of Contents for 3470

Page 1: ...andi filari dell impianto tramite l interfaccia trasmittente L N NT4576N HC HS4576 L attuatore radio basic può essere installato nel retrofrutto ed è dotato di cavetti per il collegamento in ingresso di un interruttore o pulsante tradizionale DICHIARAZIONE DI CONFORMITÀ L articolo 3470 è conforme ai requisiti essenziali della direttiva 1999 5 CE in quanto rispetta le seguenti norme ETSI EN 300 220...

Page 2: ...tagli della configurazione fare riferimento alle tabelle seguenti Descrizione Combinazione configuratore in M e tipo di contatto esterno Pulsante Interruttore ON OFF ciclico Nessun configuratore Modalità monostabile Se in stallato in un sistema My Home l attuatore ignora i comandI di tipo Ambiente e Generale PUL Modalità ON OFF Variazioni sui fronti toggle O I ON temporizzato 1 8 Nella tabella son...

Page 3: ...ns of the transmitting interface L N NT4576N HC HS4576 The basic radio actuator can be installed in the socket on the back and has cords for the incoming connection of a traditional switch or pushbutton DECLARATION OF CONFORMITY Item 3470 conforms to the essential requirements of directive 1999 5 CE because it respects the following standards ETSI EN 300 220 3 ETSI EN301 489 3 EN60669 2 1 Year of ...

Page 4: ...ys For details of the configuration refer to the following tables Description Combination configurator in M and type of external contact Pushbutton Switch ON OFF cyclical No configurator Monostablemode Ifinstalled in a My Home system the actuator ignores the Area and General commands PUL ON OFF mode Variations on the fronts toggle O I Timed ON 1 8 The table lists the modes of operation with the config...

Reviews: