46
T401S Indicator User Instructions
Supervisor menu
8.2.1 Accumulator
Super
Setpoint
Accum
1.
With the Accumulator application active, access the Supervisor menu using
password 1793. Refer to
Accessing the menus on page 25
for instructions.
From
SuPEr
, press
SELECT
…
SEtPnt
is displayed.
2.
Press
UNITS
…
AccuM
is displayed. Use this to set the items relating to accumulation.
Under
AccuM
you can do the following:
l
Enable/Disable the ability to print the accumulated total (
Prt tot
).
l
Key in a print format number for printing the total accumulated weight
information (
tot FMt
).
l
Enable/Disable the ability to clear the total accumulation information
when the total is printed (
clr tot
).
l
Reset the accumulator memory channel value to 0 (
rESEt
).
The following steps describe the procedure to set these items.
Print total
Accum
Print Total
3.
From
AccuM
, press
SELECT
…
Prt tot
is displayed. This stands for print total.
4.
Press
SELECT
…
oFF
is displayed.
5.
Press
ZERO
to keep the print total function disabled or press
UNITS
to toggle
to
on
and press
ZERO
to enable printing of the accumulated total …
Prt tot
is displayed.
If enabled, during normal operation the user can press and hold
for three seconds and the selected total print format (see step
) will be
sent out any port that is set up to printed. The display will flash
Prn-tot
.
Total format
Accum
Print Total
Total Format
6.
Press
UNITS
…
tot FMt
is displayed. This stands for the total print format.
7.
Press
SELECT
…
The current print format number is displayed with a flashing right-most
digit. (Default is format 8)
8.
Press
ZERO
to accept the existing setting or key in a new format number and
press
ZERO
…
tot FMt
is displayed.