4.
System Specification
4.1.
Single or Dual Port Wall Mount Charging Station
Model Numbers:
EVP-2001-30-W-001, EVP-2002-30-W-001,
EVP-2001-40-W-001, EVP-2002-40-W-001, EVP-2001-70-W-0001
SKUs:
L2W-30-240-16, L2W-30-240-15, L2W-40-240-16, L2W-40-240-15, L2W-70-240-16
PARAMETER
SINGLE/DUAL 30A
SINGLE/DUAL 40A
SINGLE 70A
Power per Port
7.2kW (240VAC @30A)
9.6kW (240VAC @ 40A) 16.8kW (240VAC @ 70A)
Electrical Service
Power
240/208 VAC, 30A Load
with 40A Branch
Circuit per Port
240/208 VAC, 40A Load
with 50A Branch
Circuit per Port
240/208 VAC, 70A Load
with 100A Branch
Circuit per Port
Service Panel
40A Breakers per Port
(No GFCI)
50A Breakers per Port
(No GFCI)
100A Breakers per Port
(No GFCI)
Service Wiring
3-Wire (L1, L2, Earth Ground)
Functional Interface
Connector Type
SAE J1772
Charging Protocol
SAE J1772
Standard Cable Length
25 ft
Cable Retractor
Optional (Cable 18 ft w/ Cable Management)
LCD Display
500 Nits, 7" Color, 800 x 480, UV Protected
Card Reader
ISO 14443 Type A & B, ISO 18092 NFC
Safety & Connectivity
Ground Fault Detection
20 mA
Plug-Out Detection
SAE J1772
Power Measurement
(opt)
Accuracy: 1%
–
5%
Power Report Interval
Every 15 minute on the hour
Wireless
2.4 GHz Wi-Fi (802.11 b/g/n)
Wide Area Network
4G LTE Modem, Wi-Fi, Ethernet
Communication
Protocols
OCPP 1.5 and 1.6 Compliant
Safety and Operation
Enclosure Rating
NEMA 3R
Regulatory Compliance
ETL Certified for USA and cUL Certified for Canada;
Complies with UL 2594, UL 2231-1, UL 2231-2, and NEC Article 625,
EMC: FCC Part 15 Class A
Operating Temperature
–
3
0°C to +60°C (
–
22°F to 140°F)
Storage Temperature
–
50°C to +80°C (
–
58°F to 176°F)
Humidity
95% Non-Condensing
Specifications are subject to change, without prior notice.