AC Level 2 Charger
INSTALLATION AND USER’S MANUAL
Page
31
of
59
This document is a
Property of BTCPower Inc.
and shall not be
copied, reproduced, or used as the basis for sale or manufacture
of apparatus without written permission.
09-Mar-20
Revision
T
Single / Dual System
Electrical Connection
Single Sided Charger Connection
•
Two (2) appropriately gauged hot leads (refer to local electrical code)
•
One (1) appropriately gauged ground (green) lead
•
Electrical conduit per all applicable state and federal regulations
•
AC input power should be inserted through bottom of EVSE enclosure
•
Electrical connections shall be made as specified in this section
NOTE
For the dual units, two separate line pairs need to be connected from independent service
panel breakers of the appropriate rating. Each hot lead should measure 120VAC to ground.
Service Connection
Electrical Input
AC Voltage
Single Port
208/240 VAC
Dual Port
208/240 VAC
Current
Input Power
Connection
Service Panel
Breaker
Current
Input Power
Connection
Service Panel
Breaker
Standard
(recommend 10
–
8AWG)
30A
one 50A
branch
circuit
40A dual
pole
(non-GFCI
type)
30A x 2
two
independent
40A branch
circuits
40A dual pole
(non-GFCI
type) x 2
Standard
(recommend 8
–
6AWG)
40A
one 50A
branch
circuit
50A dual
pole
(non-GFCI
type)
40A x 2
two
independent
50A branch
circuits
50A dual pole
(non-GFCI
type) x 2
Standard
(recommend 6
–
3AWG)
70A
one 100A
branch
circuit
100A dual
pole
(non-GFCI
type)
- - -
- - -
- - -
Service Panel GFCI
Do not provide external GFCI as it may conflict with internal GFCI (CCID)
Wiring Standard
3-wire (L1, L2, earth)
5-wire (L1, L1, L2, L2, earth)
For a 3-phase system, the 2 ports should be
distributed between 2 different phases
(e.g. L1 & L2, and L2 & L3)
To reduce the risk of fire, connect only to a circuit provided with the appropriate maximum
branch circuit overcurrent protection (40A, 50A, & 100A for 30A, 40A, and 70A output rating,
respectively) in accordance with the ANSI/NFPA 70 National Electrical Code. On a dual-port
charger, this circuit breaker is for each port.
INSTALLATION