Manual PRO v.3
69 / 78
4.1.6.2- Adjustment of the set value (Max. PPM)
En el cual se instala una sonda de cloro libre (OPCIONAL)
In this case, adjust the value in ppm as required. A value between 1ppm and
1.5ppm is correct.
NOTE: if working in automatic, you can also adjust the production percentage
from 0% to 100%,
NOTE: PRO200 model is the only one which ORP and Free Chlorine
regulation is available. Free Chroline regulation is only allowed in
PRO250, 500, 750 and 1000.
4.1.2.2.3- Super chlorination
Select this option if you require super-chlorination of your swimming pool,
bearing in mind the following:
-
Without a Temperature probe, super-chlorination will be carried out for
24 hours. If filtration is stopped, super-chlorination is suspended.
4.1.2.2.4- Free chlorine probe calibration
If you have a free chlorine probe, a menu will appear for you to calibrate it.
Once the reading has stabilized and the chlorine measurement has been taken
with
DPD1
,
adjust the
PPM
value provided by the DPD1 measurement.
4.1.2.3- pH menu
You can access the pH menu from the main menu by pressing
OK