Recommended installation (PRO750)
1. FILTRATION
2. CONTROL PANEL
3. FLOW SWITCH
4. ELECTROLYSIS CELL
5. PRO750 UNIT(*)
•
(*) The PRO250, PRO500, PRO750 and PRO1000 units follows the same
hydraulic scheme, connecting
in parallel
as many cells as power
modules.
•
It is highly recommended to install a by-pass system, to be able to block
the water flow in each cell for maintenance purposes.
3.2.2- PRO/2 kit (free chlorine) Optional in EVO equipment
The amperometric measurement kit, allows to obtain a ppm free chlorine
Reading from your wimming pool. This sensor is wimming a 3-electrode
header, which is separated from the water through a membrane. This ppm
measure has a low dependency of pH and isocyanuric acid, and it can be also
installed in sea water wimming pools (this option to be asked to BSV
Electronic). Please follow carefully the installation, calibration and maintenance
instructions to ensure a perfect setup of the kit.