Default settings
9
5
ekr 500 web guiding controller
EDV No.: MD.299.01.06
Chapter: 9
with removable control panel
Date:
29.07.08
Page:
76/86
9.1.2 Device address of
the control panel
Setting the control panel device address is carried out via the
rotary switch
S1
on the control panel board.
The rotary switch
S1
is mounted behind stop
B
on the back of the
control panel.
The device address of the control panel is preset to “
1
“ by
manufacturer (delivery state).
You are only allowed to modify the device address
if authorised to do so by the manufacturer!
Danger from mains voltage!
The plug of the control panel connection cable must
be disconnected from the controller before you open
the control panel!
Set device adress:
1. Unplug the connecting cable connection from the control panel on
the controller.
2. Carefully remove stop
B
from the back of the control panel.
3. Check the setting of the rotary switch
S1
on the control panel
board. The rotary switch
S1
must be set to position “
1
“.
4. Switch the rotary switch
S1
to position “
1
“ if necessary.
5. Replace the stop.
6. Plug the control panel connecting cable plug back in to the
controller.
Rotary switch S1
0 1 2
3
45
67
8
9
Stop B