Start-up
6
11
ekr 500 web guiding controller
EDV No.: MD.299.01.06
Chapter: 6
with removable control panel
Date:
29.07.08
Page:
51/86
Step 2: Set position for software limit switch 1
5. Move guiding device to the desired position for software limit
switch 1 (towards sensor 1) using the
arrow keys
.
The position indicator for software limit switch 1
shows the actual value supplied by the position
feedback of the actuator.
6. Press key “
Sensor 1
“.
The position for software limit switch 1 is stored.
The symbol “s
ensor 1
“ is represented inversely.
Step 3: Set position for software limit switch 2
7. Move guiding device to the desired position for software limit
switch 2 (towards sensor 2) using the
arrow keys
.
The position indicator for software limit switch 2
shows the actual value supplied by the position
feedback of the actuator.
8. Press key “
Sensor 2
“.
The position for software limit switch 2 is stored.
The symbol “s
ensor 2
“ is represented inversely.
Step 4: Set servo-center position
9. Move actuator to the desired center position for the guiding
device using the
arrow keys
.
The position indicator for the servo-center position
shows the actual value supplied by the position
feedback of the actuator.
10. Press key “
Servo-center
“.
The actual position is stored as servo-center position.
The symbol “
servo-center
“ is represented inversely.
Step 5: Exiting the settings
11. Press key “
ENTER
“.
The setup menu will be closed.
All modified parameter values are stored.
or
or
or