Assembly
4
9
ekr 500 web guiding controller
EDV No.: MD.299.01.06
Chapter: 4
with removable control panel
Date:
29.07.08
Page:
26/86
4.3 Assembly of the
control panel
4.3.1 General
This chapter describes the procedure for installing the control
panel when using the controller with the control panel removed
(see chapter 1.4.1.3).
Strong electromagnetic fields in the vicinity of the
control panel might cause operating failures.
When installing in a control console or a control
station you must ensure that the control panel is
not mounted close to components that use mains
power or power lines.
Always maintain a minimum clearance of 100 mm!
4.3.1.1 Installation
versions
The control panel enclosure enables the following installations
versions to be used:
1.
Wall mounting
Mount the control panel on a level surface.
See chapter 4.3.2 for the procedure.
2.
Control console mounting
Mount the control panel in an existing on-site control console or
a control station.
See chapter 4.3.3 for the procedure.
The ekr 500 installation kit (available as an option)
is required (BST order number 133 459) for
console installation.
4.3.1.2 Cable
extension
An extension cable (optional extra) is required for connection of the
control panel to the controller.
Cable extensions are available in the following lengths:
Cable length
BST order number
2 m
131 993
5 m
131 994
10 m
131 995
It is also possible to combine different cable lengths.
The maximum permitted 20 m full length between
the controller and control panel must never be
exceeded!