background image

 

 Motor-driven blocking device EasyLock 

 

Installation instruction 

8360.0 

 

 

8360Err_en.doc

 

Version  

Page 9 

3.2.1  Connection of several blocking devices 

You can connect several blocking devices in series so that they will close one after another.  
The low tension side can be used by switching on LEDs to display the status. 

Connect several blocking devices in series 

 

8360Kas.png 

Illustration 3.7 –Connecting several blocking devices in series 

3.3  Commissioning  

When  impressing  the  operating  voltage  on  the  blocking  device  will  open  up  in  any  case 
independent from the status of the inputs. 
Functional check: 

  Close and open the blocking device when the door is closed. In doing so, check the following 

functions: 

Closing or opening time maximum about ½ second. 

The locking bolt must neither contact nor interlock on the counterpart. The locking bolt 
extends without several locking trials. 

The locking bolt can extend at full length since otherwise it would open up again after 
several locking trials. 

  If the functionality is incorrect then check the wiring on the basis of the signal descriptions 

and the examples for switching on described in chapter 3.2

4  Trouble shooting 

In case of malfunctions, please check the following points: 

  Check wiring: 

Are all conductions correctly switched? 

  Check control signals: 

Is the distribution voltage of +12 V available on the blocking device? 
Is the necessary drive signal available on the blocking device? 

  Check the installation: 

Does the locking bolt extend at full length? 
Does the locking bolt contact the counterpart? 

If  the  protected  area  remains  obstructed  first  use  the  electrical  emergency  opening  options 
(Chapter 4.1)  and  if  this  is  ineffective,  use  the  mechanical  emergency  opening  options 
(Chapter 4.2)

Summary of Contents for 108360.0

Page 1: ...8360Err_en doc Version Page 1 Installation instruction Motor driven blocking device EasyLock 108360 VdS Class C G 107 102 ...

Page 2: ... and communication of its contents is not allowed if it is not expressively allowed Any infringement obliged to compensation All rights reserved We have checked if the content of the printout complies with the described components Nonetheless we cannot exclude any deviations so that we do not take any liability for the complete compliance The information in this printout are regularly checked and ...

Page 3: ...2 Installation 5 2 1 Assembly of the blocking device 5 2 2 Assembly of the counterpart 6 2 3 Emergency opening 6 3 Switching on 7 3 1 Connection to the test device 8322 0 7 3 2 Connection 8 3 2 1 Connection of several blocking devices 9 3 3 Commissioning 9 4 Trouble shooting 9 4 1 Electrical emergency opening 10 4 2 Mechanic emergency opening 10 4 3 Sluggish bolt 10 4 4 Replacing the bolt 11 4 5 P...

Page 4: ... connection is performed using a 4 pin connecting cable Distribution voltage 12 V Distribution voltage 0 V Entry opened closed 0 V Bolt extends door locked open or 12 V Bolt moved in Exit status opened closed active 0 V with blocking bolt moved out Drive with statistic signal several blocking devices are connectable Feedback signal of the bolt position Easy installation in the door frame Only the ...

Page 5: ...ce for a cable loop behind the hole for the blocking device or in the further cable duct so that sufficient cable reserves are available to extend the blocking device for service purposes The installation direction of the flange should be selected preferably in a way that the power on the bolt will come from the fixing screws of the blocking device also refer to figure 4 1 The exact installation d...

Page 6: ...d position 5 Open the locking device by using the test device 6 Open the door 7 On the door leaf you can recognize a color circle which shows the exact position of the counterpart 8 Mark the center using a center punch and drill the hole according to the counterpart For the installation dimensions of the counterparts please refer to the technical data sheet also see chapter 6 9 Assemble the counte...

Page 7: ... extended 8360Ans png Illustration 3 1 Connection plan blocking device Inputs and outputs of the blocking device Signal Lead color Description 12 V white Tension distribution 12 V 0 V brown Tension distribution 0 V Input green Input Closed 0 V Closed open or 12 V Opened Output yellow Open drain exit active 0 V Display of the status closed 3 1 Connection to the test device 8322 0 During the commiss...

Page 8: ...esidual current of a view µA e g due to the corresponding burglary alarm center protective circuit varistors transildiods etc it may occur that the blocking device will not correctly react when changing over the output from active to inactive In order to work properly a pull up resistance can be put between the input and 12 V The amount of resistance shall not exceed 1 MΩ 8360ES2a png Illustration...

Page 9: ...must neither contact nor interlock on the counterpart The locking bolt extends without several locking trials The locking bolt can extend at full length since otherwise it would open up again after several locking trials If the functionality is incorrect then check the wiring on the basis of the signal descriptions and the examples for switching on described in chapter 3 2 4 Trouble shooting In ca...

Page 10: ...emergency opening If the electrical emergency opening options is not successful you can apply the mechanic emergency opening options Predetermine breaking point at the locking bolt The locking bolt of the blocking device possesses a predetermine breaking point which responds at a force of more than 1 kN about 100 kg at max 3 mm distance from the fixing flange Spare Locking bolts are available unde...

Page 11: ... the blocking device refer to the drawing on the right The two guiding noses on the bolt need to fit exactly to the guiding grooves of the housing After a few seconds the bolt will be moved in If you put the bolt the other way around by mistake it will automatically be ejected after a few seconds When the bolt is correctly inserted turn in a new screw cap up to the stop 8360BA2 eps Illustration 4 ...

Page 12: ...ad for min 5 sec Bolt path 12 mm Maximum distance housing flange to counterpart 8 mm for VdS Applications 3 mm Closing Opening time 0 3 s at 14 V DC operating voltage Locking force 5 N at 14 V DC operating voltage Admissible shearing force 1 0 kN at max 3 mm distance from the flange 0 5 kN at 8 mm distance from the flange Operating temperature Storage temperature range 25 C 60 C 40 C 70 C Ecologic...

Reviews: