Motor-driven blocking device EasyLock
Installation instruction
8360.0
8360Err_en.doc
Version
Page 9
3.2.1 Connection of several blocking devices
You can connect several blocking devices in series so that they will close one after another.
The low tension side can be used by switching on LEDs to display the status.
Connect several blocking devices in series
8360Kas.png
Illustration 3.7 –Connecting several blocking devices in series
3.3 Commissioning
When impressing the operating voltage on the blocking device will open up in any case
independent from the status of the inputs.
Functional check:
•
Close and open the blocking device when the door is closed. In doing so, check the following
functions:
-
Closing or opening time maximum about ½ second.
-
The locking bolt must neither contact nor interlock on the counterpart. The locking bolt
extends without several locking trials.
-
The locking bolt can extend at full length since otherwise it would open up again after
several locking trials.
•
If the functionality is incorrect then check the wiring on the basis of the signal descriptions
and the examples for switching on described in chapter 3.2.
4 Trouble shooting
In case of malfunctions, please check the following points:
•
Check wiring:
Are all conductions correctly switched?
•
Check control signals:
Is the distribution voltage of +12 V available on the blocking device?
Is the necessary drive signal available on the blocking device?
•
Check the installation:
Does the locking bolt extend at full length?
Does the locking bolt contact the counterpart?
If the protected area remains obstructed first use the electrical emergency opening options
(Chapter 4.1) and if this is ineffective, use the mechanical emergency opening options
(Chapter 4.2).