Motor-driven blocking device EasyLock
Installation instruction
8360.0
8360Err_en.doc
Version
Page 7
3 Switching on
The switching on is performed via a 4-pin
cable. Two leads are required for the
voltage distribution - nominal 12 V DC. The
drive is performed with a static signal
0 V-active.
Additionally
a
revertive
communication output is available which
switches approach to 0 V if the locking bolt
is extended.
8360Ans.png
Illustration 3.1 – Connection plan blocking device
Inputs and outputs of the blocking device
Signal
Lead color
Description
+12 V
white
Tension distri12 V
0 V
brown
Tension distribution 0 V
Input
green
Input “Closed“:
0 V
“Closed“
open or +12 V
“Opened“
Output
yellow
Open drain exit, active 0 V: Display of the status “closed”
3.1 Connection to the test device 8322.0
During the commissioning and for further test
purposes you can use the test device 8322.0. For
the connection please refer to the illustration on the
right.
8322Ab2.png
Illustration 3.2 – Connection to a test device 8322.0