4421 1999 REV -
Page 8
2.2 Hydraulic Supply:
The flow and pressures required to operate each hammer in the CG range at rated energy and blow
rate are as follows: The hammers’ will work at lower flow at reduced energy and blow rate.
Model
Ram Weight
Operating
Pressure
Flow
Minimum
Pressure Relief
Setting
(kg)
(bar)
(L/min)
(bar)
CG180
12000
180-210
370
300
CG210
14000
220-250
370
300
CG240
16000
250-280
370
300
CG300
20000
280-300
400
320
2.3 Operating / storage temperature limits
a)
Operating
Subject to the use of the appropriate grade of hydraulic oil (refer to the operating manual for
the power source).
Component
Limiting
temp. °C
Comments
Control box / monitor
0
for lower temperature install in operator’s cab
Umbilical
-5
for lower temperature refer to alternative
umbilical construction
Hammer
-10
for temperatures below 0°C the hammer should be
operated at 25% energy for 10minutes after stating
from cold
Hammer
-25
oil must be circulated in hoses and hammer prior to
starting
b)
Storage
Minimum temperature -40°C
Hammer to be stored under protective cover.
Hose umbilical, control cable to be removed from hammer and stored under cover.
Control box / monitor to be stored at above 0°C.
c)
Maximum ambient temperature
40°