2.3.2
Measures to be taken after each repair
State of the appliance
Measures
Appliance has been repaired and is
functionally reliable.
•
Run tests in accordance with VDE
0701 or comparable national regula-
tions.
•
Conduct a performance test.
•
Document repair work, tests, mea-
sured values and functional reliabili-
ty.
Appliance is still defective and
not
func-
tionally reliable.
•
Clearly identify appliance as "not
functionally reliable".
•
Inform customer in writing about the
lack of functional safety.
Table 4:
Measures to be taken after each repair
2.4
Basic warning instructions
Exposed, live components!
Death from electric shock.
► Disconnect the appliance from the power supply.
► Do not touch housing, frame or components.
► If running tests while the power is on, always use a residual
current circuit-breaker.
► Ensure that the resistance of the protective conductor does not
exceed the standardised value.
Discharge current of charged capacitors!
Death from electric shock. Risk of injury from startle response.
► Disconnect the appliance from the power supply.
► Discharge capacitors.
Exposed, defective components live!
Death from electric shock.
► Disconnect the appliance from the power supply.
► Do not touch housing, frame or components.
► If running tests while the power is on, always use a residual
current circuit-breaker.
► Ensure that the resistance of the protective conductor does not
exceed the standardised value.