30
Detection Antenna: Top-left end of the meter
Probe-Contact EF-Detection (Single-pole):
For more precise indication of live wires, such
as distinguishing between live and ground connections, use one single test probe to test via
terminal COM for direct metal contact probing to achieve the most distinctive indications.
RECORD mode (MAX MIN AVG)
Function Mode
Where Available
Added Uncertainty
1)
to Specified Accuracy
Min. Volts/Amps
Signal Duration
REC Nominal Update
Rate per Second
DC
30d
300ms
10
AC
300d (
80d
2) 3)
)
460ms
5 (10
3)
)
VFD
180d
800ms
5
DC+AC
300d
2)
2s
1
nS
--
--
1
Cx
--
--
Subject to Cx Values
Hz, T1-T2
--
--
2
Ω
, T1, T2, Others
--
--
5
1)
Specified at Range Locked (Manual-ranging)
2)
Specified at AC Inputs >15% of Range for
Model 789
3)
For
Model 789
only
CREST mode (Instantaneous Peak Hold)
Accuracy: Specified accuracy
100 digits for changes > 0.35ms in duration
Availability: Voltage and Current functions
Resolution: 6000 counts
AutoHold Real-Read
TM
Accuracy: Specified accuracy
50 digits
Availability: Resistance, Continuity, LoZ AutoV, VFD Volts, Voltage and Current functions