14
Temperature (Model
319s
only)
RANGE
Accuracy
-50
o
C ~ 1000
o
C
0.5% + 3d
-58
o
F ~ 1832
o
F
0.5% + 6d
K type thermocouple range & accuracy not
included
IP-RPM* (Inductive pickup type)
RANGE
Accuracy
RPM 4
240 -20000 RPM
2 RPM
RPM 2
120 -10000 RPM
2 RPM
RPM 2M
60 -5000 RPM
2 RPM
*Measurements via inductive pickup clip
(optional purchase for Model
315s
)
Four selectable trigger levels,
Sensitivity:
Level 1: 3.0V typically
Level 2: 4.5V typically
Level 3: 6.1V typically
Level 4: 8.1V typically
IG-RPM* (Contact signal type)
RANGE
Accuracy
RPM 4
60 -20000 RPM
2 RPM
RPM 2
30 -10000 RPM
2 RPM
RPM 2M
15 -5000 RPM
2 RPM
*Measurements via test leads on Dwell, Fuel
injection-ms and ignition primary signals
Nine selectable Cylinders: 1, 2, 3, 4, 5, 6, 8, 10
& 12
Four selectable trigger levels,
Sensitivity:
Level 1: 0.8V typically
Level 2: 1.85V typically
Level 3: 3.75V typically
Level 4: 6V typically
DWELL
RANGE
Accuracy
0.0
o
~ 360.0
o
*
1.2
o
/krpm+1d
0.0%~100.0%
0.04%/krpm/cyl+2d
Specified ranges depend on engine rpm and
number of Cylinders (cyl)
*Nine selectable Cylinders: 1, 2, 3, 4, 5, 6, 8,
10 & 12
Four selectable trigger levels,
Sensitivity:
Level 1: 0.8V typically
Level 2: 1.85V typically
Level 3: 3.75V typically
Level 4: 6V typically
Fuel injection-ms detector
RANGE *
Accuracy
PFI / Multi Point Injection
0.05ms ~ 250.0ms
0.05ms+1d
0.0%~100.0%
0.04%/krpm +2d
TBI / Single Point Injection
0.05ms ~ 250.0ms
0.05ms+1d
0.0%~100.0%
0.04%/krpm/cyl +2d
*Specified range depends on engine rpm
Selectable ± trigger slopes
Four selectable trigger levels,
Sensitivity:
Level 1: 0.8V typically
Level 2: 1.85V typically
Level 3: 3.75V typically
Level 4: 6V typically
Hz (Line-level) @ ACV & DCV
Function
Sensitivity
(Sine RMS)
Range
6V
0.5V
10Hz - 10kHz
60V
5V
10Hz - 50kHz
600V
50V
10Hz - 50kHz
1000V
500V
45Hz - 1kHz
Accuracy: 0.1%+3d