21
Diode Tester
RANGE
Accuracy
3.000V
0.9% + 2d
Test Current: 0.3mA typical
Open Circuit Voltage: < 3.2VDC typical
DC
A & AC
A (Model 239R only)
RANGE
Accuracy
Burden Voltage
1)
DC
A
200.0
A, 2000
A
0.7% + 3d
2.5mV/
A
AC
A
(50H
Z
~
400H
Z
)
200.0
A, 2000
A
1.0% + 3d
2.5mV/
A
1)
Combination PTC protective impedance is being used
DCA & ACA (Models 237R & 239R only)
RANGE
Accuracy
Burden Voltage
DCA
6.000A, 10.00A
1)
0.7% + 3d
0.04V/A
ACA
(50H
Z
~
400H
Z
)
6.000A
2)
, 10.00A
1)
1.0% + 3d
0.04V/A
1)
10A continuous, >10A to 20A for 30 seconds max with 5 minutes cool down interval
2)
<5d non-zero residue may appear when backlight is on, which will not affect the
specified measuring range and accuracy
Temperature (Model 239R only)
RANGE
Accuracy
1) 2)
-40.0
o
C ~ 99.9
o
C
1% + 1
o
C
100
o
C ~ 400
o
C
-40.0
o
F ~ 99.9
o
F
1% + 2
o
F
100
o
F ~ 752
o
F
1)
Accuracies assume meter interior and the ambient have reached the same temperature
(isothermal stage) for a correct junction voltage compensation. Allow enough settling time for
a significant change of ambient temperature. It can take up to an hour for changes > 5°C.
2)
Type-K thermocouple range & accuracy not included