22
Line Frequency (Models 237R & 239R only)
Function
Sensitivity (Sine RMS)
Range
60mV, 600mV
50mV
10Hz - 50kHz
6V
5V
10Hz - 50kHz
60V
10V
10Hz - 50kHz
600V
50V
10Hz - 1kHz
1000V
500V
10Hz - 1kHz
VFD 600V
50V
10Hz - 1kHz
VFD 1000V
500V
10Hz - 1kHz
200
A
1)
, 2000
A
1)
500
A
10Hz - 5kHz
6A, 10A
8A
50Hz - 1kHz
1)
Available for Model 239R only
Accuracy: 0.03% + 2d
Non-Contact EF-Detection (Models 237R & 239R only)
Bar-Graph
Indication
EF-H (Hi Sensitivity)
EF-L (Lo Sensitivity)
Typical Voltage (Tolerance)
-
10V (3V ~ 19V)
40V (16V ~ 71V)
- -
20V (10V ~ 38V)
80V (32V ~ 142V)
- - -
40V (21V ~ 79V)
160V (63V ~ 285V)
- - - -
80V (40V ~ 156V)
300V (105V ~ 608V)
- - - - -
160V (>80V)
500V (>300V)
Indication: Bar-graph segments & audible beep tones proportional to the field strength
Detection Frequency: 50/60Hz
Detection Antenna: Top-left end of the meter
Probe-Contact EF-Detection: For more precise indication of live wires, such as distinguishing
between live and ground connections, use direct contact testing with one single test-probe
via the input terminal COM or V. The COM terminal (Black) has the best sensitivity.
&
3-Phase Rotation function
Hi-sensitivity mode
Voltage range: 0.4V ~ 1000V
Frequency range: 3Hz ~ 400Hz
Normal-sensitivity mode
Voltage range: 65V ~ 1000V
Frequency range: 35Hz ~ 400Hz
Summary of Contents for BM236R
Page 1: ...USER S MANUAL BM236R BM237R BM239R ...
Page 9: ...8 ...