—34—
HEAT PUMP HEATING PERFORMANCE Continued
* The Btuh heating capacity values shown are net “integrated’’ values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
† The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB—Entering Dry Bulb
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
°
F
–3
7
17
27
37
47
57
EDB
CFM
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
Total
Int*
Kw†
697C060-A Outdoor Section With FK4CNB006 Indoor Section
65
1575
28.0
25.8
3.81
33.2
30.6
4.02
39.1
35.6
4.24
45.3
40.3
4.4
52.8
48.0
4.81
61.2
61.2
5.20
71.0
71.0
5.73
1750
28.3
26.0
3.82
33.5
30.8
4.01
39.4
35.9
4.22
45.7
40.5
4.4
53.2
48.4
4.76
61.7
61.7
5.14
71.7
71.7
5.65
2012
28.6
26.3
3.84
33.9
31.1
4.02
39.7
36.2
4.21
46.1
40.9
4.4
53.7
48.9
4.72
62.3
62.3
5.09
72.0
72.0
5.52
70
1575
27.7
25.5
3.98
32.9
30.3
4.21
38.7
35.3
4.45
44.9
39.8
4.7
52.1
47.5
5.05
60.5
60.5
5.45
70.2
70.2
5.99
1750
28.0
25.7
3.99
33.2
30.5
4.20
39.0
35.6
4.43
45.2
40.1
4.6
52.6
47.8
4.99
61.0
61.0
5.38
71.6
71.6
5.91
2012
28.3
26.0
4.02
33.5
30.8
4.21
39.4
35.9
4.42
45.6
40.5
4.6
53.1
48.3
4.95
61.6
61.6
5.32
71.5
71.5
5.84
75
1575
27.4
25.2
4.16
32.6
30.0
4.41
38.3
35.0
4.67
44.4
39.4
4.9
51.6
47.0
5.29
59.8
59.8
5.72
69.3
69.3
6.27
1750
27.6
25.4
4.16
32.9
30.2
4.40
38.6
35.2
4.64
44.7
39.7
4.9
52.0
47.3
5.23
60.3
60.3
5.64
70.0
70.0
6.17
2012
28.0
25.7
4.19
33.2
30.5
4.41
39.0
35.6
4.63
45.2
40.1
4.8
52.5
47.8
5.18
60.9
60.9
5.57
70.7
70.7
6.10
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
F(A,B)4AN(F,B,C)
060
1.00
1.09
CD3(A,B)A
060
1.00
1.17
FB4ANB
070
1.00
1.03
CE3AA
060
1.00
1.10
FC4BN(F,B)
060
1.00
1.09
CJ5A/CK5A/CK5BA
060
1.00
1.12
FC4BNB
070
1.00
1.03
CK5A/CK5A/CK5BX
060
1.00
1.06
FG3AAA
060
1.00
1.13
CK3BA
060
1.00
1.12
FK4BNB
006
1.00
1.01
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
FK4CNB
006
1.00
1.00
CC5A/CD5A/CD5BA
060
1.00
1.19
CC5A/CD5A/CD5BA
060
1.00
1.18
CC5A/CD5A/CD5BW
060
1.00
1.10
CC5A/CD5A/CD5BW
060
1.00
1.11
CD3(A,B)A
060
1.00
1.19
CD3(A,B)A
060
1.00
1.18
CE3AA
060
1.00
1.11
CE3AA
060
1.00
1.11
CJ5A/CK5A/CK5BA
060
1.00
1.11
CJ5A/CK5A/CK5BA
060
1.00
1.12
CK5A/CK5A/CK5BX
060
1.00
1.06
CJ5A/CK5A/CK5BN
060
1.00
1.12
CK3BA
060
1.00
1.11
CJ5A/CK5A/CK5BX
060
1.00
1.07
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CK3BA
060
1.00
1.12
CC5A/CD5A/CD5BA
060
1.00
1.19
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BW
060
1.00
1.11
CC5A/CD5A/CD5BA
060
1.00
1.17
CD3(A,B)A
060
1.00
1.19
CC5A/CD5A/CD5BW
060
1.00
1.10
—
—
—