DETAILED COOLING CAPACITIES CONTINUED
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES deg F
75
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
Sys-
tem
KW*
*
Capacity
MBtuh†
Total
Sys-
tem
KW*
*
Capacity
MBtuh†
Total
Sys-
tem
KW*
*
Capacity
MBtuh†
Total
Sys-
tem
KW*
*
Capacity
MBtuh†
Total
Sys-
tem
KW*
*
Capacity
MBtuh†
Total
Sys-
tem
KW*
*
Total
Sens
‡
Total
Sens
‡
Total
Sens
‡
Total
Sens
‡
Total
Sens
‡
Total
Sens
‡
265ANA036---B Outdoor Section With FX4CNF042 Indoor Section
1050
72
42.99
22.20
2.25
41.05
21.45
2.51
39.02
20.67
2.79
36.86
19.85
3.11
34.54
18.98
3.45
32.00
18.04
3.82
67
39.02
27.33
2.23
37.23
26.56
2.49
35.34
25.75
2.77
33.34
24.91
3.09
31.18
24.01
3.43
28.83
23.04
3.80
63
36.20
26.40
2.22
34.51
25.62
2.48
32.73
24.80
2.76
30.84
23.95
3.07
28.81
23.04
3.41
26.59
22.06
3.78
62
35.49
32.46
2.22
33.85
31.64
2.48
32.13
30.77
2.76
30.33
29.81
3.07
28.51
28.51
3.41
26.74
26.74
3.78
57
34.32
34.32
2.21
33.01
33.01
2.47
31.62
31.62
2.76
30.13
30.13
3.07
28.52
28.52
3.41
26.74
26.74
3.78
1200
72
43.88
23.28
2.29
41.86
22.52
2.54
39.75
21.72
2.83
37.51
20.89
3.14
35.10
20.01
3.49
32.48
19.06
3.86
67
39.84
29.07
2.27
37.97
28.28
2.53
36.00
27.46
2.81
33.92
26.60
3.12
31.69
25.68
3.47
29.26
24.69
3.84
63
36.96
28.03
2.26
35.20
27.23
2.51
33.35
26.40
2.80
31.39
25.53
3.11
29.29
24.60
3.45
27.00
23.59
3.82
62
36.31
34.75
2.25
34.63
33.86
2.51
32.89
32.89
2.80
31.30
31.30
3.11
29.59
29.59
3.45
27.71
27.71
3.82
57
35.74
35.74
2.25
34.35
34.35
2.51
32.87
32.87
2.79
31.30
31.30
3.11
29.59
29.59
3.45
27.71
27.71
3.82
1350
72
44.58
24.31
2.32
42.49
23.53
2.58
40.31
22.72
2.86
38.00
21.88
3.18
35.52
20.99
3.52
32.84
20.03
3.89
67
40.46
30.73
2.30
38.53
29.93
2.56
36.50
29.09
2.84
34.37
28.21
3.16
32.07
27.27
3.50
29.60
26.24
3.87
63
37.55
29.58
2.29
35.73
28.77
2.55
33.82
27.92
2.83
31.81
27.03
3.14
29.65
26.07
3.48
27.32
25.03
3.85
62
37.06
36.76
2.29
35.47
35.47
2.55
33.93
33.93
2.83
32.27
32.27
3.15
30.49
30.49
3.49
28.52
28.52
3.86
57
36.94
36.94
2.29
35.47
35.47
2.55
33.93
33.93
2.83
32.28
32.28
3.15
30.49
30.49
3.49
28.52
28.52
3.86
Cooling Indoor Model
Capacity
Power
Furnace Model
*FX4CN(B,F)042
1.00
1.00
FE4ANB006
1.00
0.96
FE4ANF002
0.96
0.96
FE4ANF003
0.97
0.97
FE4ANF005
1.00
0.96
FE5ANB004
1.00
0.96
FF1ENP036
0.96
1.07
FV4BNB006
1.00
0.96
FV4BNF002
0.96
0.96
FV4BNF003
0.97
0.97
FV4BNF005
1.00
0.96
FX4CN(B,F)036
0.98
0.98
FY4ANF036
0.96
1.07
FY4ANF042
0.97
1.06
CAP**3614A**
0.93
1.01
CAP**3617A**
0.96
1.04
CAP**3621A**
0.96
1.04
CAP**4221A**
0.97
1.06
CAP**4224A**
0.97
1.06
CNPF*3618A**
0.96
1.07
CNPH*3617A**
0.96
1.04
CNPH*4221A**
0.97
1.06
CNPV*3617A**
0.96
1.04
CNPV*3621A**
0.96
1.04
CNPV*4221A**
0.97
1.06
CSPH*3612A**
0.96
1.04
CSPH*4212A**
0.97
1.01
CAP**3614A**
0.93
0.97
315(A,J)AV036070
CNPH*3617A**
0.95
0.99
315(A,J)AV036070
CNPH*4221A**
0.96
0.96
315(A,J)AV036070
CSPH*3612A**
0.96
0.96
315(A,J)AV036070
CSPH*4212A**
0.97
0.97
315(A,J)AV036070
CAP**3617A**
0.96
0.96
315(A,J)AV048090
CNPH*3617A**
0.96
0.96
315(A,J)AV048090
CNPH*4221A**
0.97
0.93
315(A,J)AV048090
CNPV*3617A**
0.96
0.96
315(A,J)AV048090
CSPH*3612A**
0.96
0.96
315(A,J)AV048090
CSPH*4212A**
0.97
0.97
315(A,J)AV048090
CAP**3621A**
0.96
0.96
315(A,J)AV060110
CAP**4221A**
0.97
0.97
315(A,J)AV060110
CNPH*3617A**
0.96
0.96
315(A,J)AV060110
CNPH*4221A**
0.97
0.93
315(A,J)AV060110
CNPV*3621A**
0.96
0.96
315(A,J)AV060110
CNPV*4221A**
0.97
0.97
315(A,J)AV060110
CSPH*3612A**
0.96
0.96
315(A,J)AV060110
CSPH*4212A**
0.97
0.97
315(A,J)AV060110
CAP**4224A**
0.97
0.97
315(A,J)AV066135
CNPH*3617A**
0.96
0.96
315(A,J)AV066135
CNPH*4221A**
0.97
0.93
315(A,J)AV066135
CSPH*3612A**
0.96
0.96
315(A,J)AV066135
CSPH*4212A**
0.97
0.97
315(A,J)AV066135
CAP**4224A**
0.97
0.93
315(A,J)AV066155
CNPH*3617A**
0.96
0.96
315(A,J)AV066155
CNPH*4221A**
0.97
0.93
315(A,J)AV066155
CSPH*3612A**
0.96
0.96
315(A,J)AV066155
CSPH*4212A**
0.97
0.93
315(A,J)AV066155
Cooling Indoor Model
Capacity
Power
Furnace Model
CAP**4224A**
0.96
0.96
355AAV042040
CNPH*3617A**
0.95
0.99
355AAV042040
CNPH*4221A**
0.96
0.96
355AAV042040
CSPH*3612A**
0.96
0.96
355AAV042040
CSPH*4212A**
0.96
0.96
355AAV042040
CAP**3617A**
0.96
0.96
355AAV042060
CNPH*3617A**
0.96
1.00
355AAV042060
CNPH*4221A**
0.97
0.97
355AAV042060
CNPV*3617A**
0.96
1.00
355AAV042060
CSPH*3612A**
0.96
0.96
355AAV042060
CSPH*4212A**
0.96
0.96
355AAV042060
CAP**3621A**
0.96
1.00
355AAV042080
CAP**4221A**
0.96
0.96
355AAV042080
CNPH*3617A**
0.95
0.99
355AAV042080
CNPH*4221A**
0.97
0.97
355AAV042080
CNPV*3621A**
0.95
0.99
355AAV042080
CNPV*4221A**
0.96
0.96
355AAV042080
CSPH*3612A**
0.96
0.96
355AAV042080
CSPH*4212A**
0.96
0.96
355AAV042080
CAP**3621A**
0.96
0.96
355AAV060080
CAP**4221A**
0.97
0.97
355AAV060080
CNPH*3617A**
0.96
1.00
355AAV060080
CNPH*4221A**
0.97
0.97
355AAV060080
CNPV*3621A**
0.96
1.00
355AAV060080
CNPV*4221A**
0.97
0.97
355AAV060080
CSPH*3612A**
0.96
0.96
355AAV060080
CSPH*4212A**
0.97
0.97
355AAV060080
CAP**3621A**
0.96
0.96
355AAV060100
CAP**4221A**
0.97
0.97
355AAV060100
CNPH*3617A**
0.96
1.00
355AAV060100
CNPH*4221A**
0.97
0.97
355AAV060100
CNPV*3621A**
0.96
0.96
355AAV060100
CNPV*4221A**
0.97
0.97
355AAV060100
CSPH*3612A**
0.96
0.96
355AAV060100
CSPH*4212A**
0.97
0.97
355AAV060100
CAP**4224A**
0.97
0.97
355AAV060120
CNPH*3617A**
0.96
0.96
355AAV060120
CNPH*4221A**
0.97
0.97
355AAV060120
CSPH*3612A**
0.96
0.96
355AAV060120
CSPH*4212A**
0.97
0.97
355AAV060120
See notes on pg. 24